Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 4CM8290 | PIN CUSHION ERRADO CONVEXO )(. | Fuga no diodo 6624 (MUR460). * Nov 95 ANC *. | ||
Philips | 4CM8290 | PEQUENO RISCO HORIZONTAL. | VERIFICAR BOBINA 5612 EM CURTO. * MAI 95 ANC *. | ||
Philips | 4CM8290 | NAO FUNCIONA (FICA COMO DESLIGADO). | VERIFICAR TRILHA QUEBRADA NO REG. 7415. * DEZ 94 ANC *. RESISTOR 3105 (47Û) ABERTO, VER TAMBEM 2109 (470µF). * AGO 95 ANC *. | ||
Philips | 4CM8290 | MANCHAS NA IMAGEM (FALTA DE PUREZA). | SE OCORRE EM ALTA RESOLUÇAO, VERIFICAR CAPACITOR 2303 (100nF). * MAI 95 ACM *. | ||
Philips | 4CM8290 | LED(S) PISCANDO. (REPETITIVAMENTE) | ALGUNS APARELHOS SAO DOTADOS COM UMA "PLACA A MAIS" A QUAL ACIONA UM CIRCUITO BLOQUEANDO O FUNCIONAMENTO DA ETAPA DE SAIDA HORIZONTAL, QUANDO O APARELHO NAO APRESENTA SINAL DE RGB, PARA MANUTENÇAO JAMPEAR M932. * DEZ 94 ES *. | ||
Philips | 4CM8290 | LARGURA EM EXCESSO | Resistor SMD 3608 (1K2) com solda fria. * Nov 95 ANC *. Fuga no diodo 6624 MUR460. * Nov 95 ANC *. Transistor 7618, 7621 (BUK453) e 100Û. * 02Dez96 JO *. | ||
Philips | 4CM8290 | FORA DE QUADRO, DESCENTRALIZADO. | VERIFICAR CAPACITOR 2303 (100nF). * MAI 95 ACM *. | ||
Philips | 4CM8290 | DESLIGA LOGO APOS LIGAR. | VERIFICAR LED 7 DESTE MODELO. * DEZ 94 ES *. CAPACITOR 2935 ABERTO (2,2µF). * AGO 95 ANC *. | ||
Philips | 4CM8290 | DESLIGA INTER. OU PROTEGE (REW 3 P/ VCR). | Solda fria no resistor SMD 3608 (1K2). * NOV 95 ANC *. | ||
Philips | 4CM8290 | DANIFICA RESISTOR | RESISTORES 3646/3650/3657, VERIFICAR FET 7624 (BSN254A). * MAI 95 ANC *. | ||
Philips | 4CM8290 | DANIFICA BOBINA OU TRAFO. | BOBINA 5613, VER TRAFO 5612 COM FUGA. * MAI 95 ANC *. | ||
Philips | 4CM8290 | CHEIRO DE QUEIMADO OU COM FUMAÇA. | VERIFICAR FET 7624 (BSN254A), RESISTORES 3636/3650/3657 DANIFICADOS. * MAI 95 ANC *. | ||
Philips | 4CM8290 | BRILHO NAO ATUA | Resistor 3533 (75K) aberto. * 26Fev96 JO *. | ||
Philips | 4CM8290 | AQUECE BOBINA | AQUECE BOBINA 5613, VER TRAFO COM FUGA 5612. * MAI 95 ANC * | ||
Philips | 4CM8290 | AO LIGAR APARECE RUIDO FORTE | CAPACITOR 2152 ALTERADO (68µF). * AGO 95 ANC *. |