Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Philips2027DCSEM TENSAO (VO, +B, HVT, ETC). Sem MAT, verificar capacitor SMD 2353. * 20Jun97 JO *.
Philips17BL2022IMAGEM NEGATIVA. INTEGRADO IC230.
Philips17BL2022EXCESSO DE DEFLEXAO R523 ABERTO. * ANC *.
Philips17BL2002TELA BRANCA, SEM RETRAÇOS. D599 COM FUGA NA PLACA DO TRC. * ECB *.
Philips17BL2002SEM SOM. (COM OU SEM IMAGEM P/ TV, VCR). S310.
Philips17BL2002SEM LARGURA (SEM DEFLEXAO HOR) RISCO VERT. CAPACITOR C383.
Philips17BL2002SEM BRILHO (VER TB.TELA1) VERIFICAR RESISTORES R450/R451.
Philips17BL2002RONCO NO SOM SUBSTITUIR C524 PARA 2N2.
Philips17BL2002NAO FUNCIONA (FICA COMO DESLIGADO). TS450/TS355/TS120/TS130. * ECB *. IC230.
Philips17BL2002NAO ABRE VERTICAL TS522. 1529.
Philips17BL2002LINHAS DE RETORNO (RETRAÇO). RESISTOR R453.
Philips17BL2002DANIFICA SEMICONDUTOR IC OU TS DANIFICA SAIDA VER NUCLEO T410 (SOLTO). RESISTOR R107 ALTERADO DANIFICA TS101. * ECB *.
Philips17BL2002DANIFICA RESISTOR RESISTORES 450/451 DANIFICADOS VER TS451 EM CURTO. * ECB *.
Philips17BL2002COM UMA OU MAIS BARRAS HORIZONTAIS VER S450.**
Philips17BL2002COM BARRA(S) OU FAIXAS VERTICAIS VER INF O6 CT 9204.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.