Dicas Reparação SANYO




Modelo - Chassis


Pesquisa: SANYO Enviar Dica Resolvida
Resultados 689
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SanyoCBP5156
No chan OSD, vol bar stops ½ way across & no B in Txt Dry joints IC001 SAA5246 Txt proc chip
SanyoCBP3024
NO SOUNDOC. PRINT EDGE OF PCB
SanyoCBP3018
Dead - LOPTr Q402 2SD1649/BU508AF s/c130v HT high at 180v as R555 47k o/c;check HT smoother & also check Q551 2SB764 in line drive (use BC640 in lieu)
SanyoCBP3012-10
Slow start upR520/521 120k
SanyoCBP3012 A3-A14
Picture blanks out intermittentlyCheck for dryjoints at transistor Q241 ( 2SA1015 ) which is in the luminance signal feed between the LA7680 jungle chip and the
SanyoCBP3012 A3
St/by only - HT present at LOP TrNo line drive - Q431 line dr tr no collector supply - Q551 2SB764 pnp s/c - used BC640 in lieu
SanyoCBP3012 A3
Pic int blanks outDry joints Q241 2SA1015 in lum signal feed
SanyoCBP3012 A3
DeadR502 3R9 6w o/c, Q513 chopper tr 2SD1710 s/c, Q553 2SC536 s/c, D515 PC1138 opto also replaced as a precaution, Q512 2SC3807 s/c (use correct replacement)
SanyoCBP3012 A3
Bright raster with fback linesNo HT to RGB stage as R557 10R was o/c (in psu)
SanyoCBP3012
HT low & no regulationQ553 2SC536 in error sensing leaky
SanyoCBP3012
Dead - no o/p from psuQ511 2SA608 s/c - now tripping as Q533 2SC536 faulty
SanyoCBP3011-15
Dead.R320/21 ( 120k ) changed value. *WARNING smoothing cap charged*
SanyoCBP3011-15
DeadR320 & 321 120k hi res
SanyoCBP3011 - 15
DeadR320 , 321 120k
SanyoCBP3011
St/by onlyPin 21 of main micro had a 48R leak to 5v rail - micro faulty


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.