Dicas Reparação SHARP




Modelo - Chassis


Pesquisa: SHARP Enviar Dica Resolvida
Resultados 1459
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SharpCA10 59DS03H
St/by only2 x 560k start up res o/c (hidden by chopper tr heatsink)
SharpCA10 59DS03H
PARTIAL FRAME COLLAPSEREPLACE F0601 F0602 AT REAR OF PCB
SharpCA10 59DS03H
NO REMOTE OR KEYPAD FUNCTIONSREPLACE R705 68K
SharpCA10 59DS03H
FRAME COLLAPSEREPLACE F602
SharpCA10 59DS03H
Field scan at top stretchedScan coils faulty - do not run for long - risk of crt neck damage
SharpCA10 59DS03H
Field - no pic at top ½ of rasterField stage is supplied with + & -ve supplies fused by F601/2. Check these & Q501/2. Q501 faulty & replaced with a IRFI9020 (uprated device)
SharpCA10 59DS03H
Dead with mains fuse o/cQ701 chopper FET s/c RH-TX0166BM22, D712 zener RH-EX0419BM22, BUH515 LOPTr - if stuck in st/by aft replacement Q702 BC338 in psu s/c
SharpCA10 59DS03H
Dead apart from power light2 x 560k start up res hidden under chopper heatsink
SharpCA10 59DS03H
Dead apart from neon glowingR703/705 68k hi res
SharpCA10 59/66DS03H
set won't start (no line drive)D602 s/c in -13V supply (RHDX0504BMZZ)
SharpCA10 59/66DS03H
partial frame collapse and foldoverreplace fuses F0601, F0602 rear of PCB, upgrade to 2.5A. If fuses Ok, check R617 22R
SharpCA10 59/66DS03H
no sound on speakers, Ok on headphonesSMD C2310 33nF leaky (45V line down to about 30V)
SharpCA10 59/66DS03H
no remote or local buttons functionR705 68k o/c (no supply to IC702)
SharpCA10 59/66DS03H
no remote or front control functionsR704, R705 68k 1W in 5V supply to Micro are high or o/c
SharpCA10 59/66DS03H
frame collapsefuse F602 o/c (QFSJ2521CEZZ)


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.