SharpCA10 59/66DS03H
excessive width with E/W errorreplace R519 100k (o/c)
SharpCA10 59/66DS03H
distortion on right channelSMD C2314 100nF leaky
SharpCA10 59/66DS03H
dead, neon light onR704 68k 1W (no 5V to Micro)
SharpCA10 59/66DS03H
dead, line drive present on base of LOPTr but it is not being turned onlack of bias to Q602 due to D605 o/c (RHDX0591BMZZ)
SharpCA10 59/66DS03H
deadC613 680nF 250V burn-up or buckled, also R613 2.2k R610 safety 33R (RRXZ0218BMZZ)
SharpCA10 59/66DS03H
bottom half of screen dark on high contract scenesreplace D514 1N4148 (leaky), feeds off frame stage to pin 22 jungle IC201
SharpCA10 59/66DS03H
bottom half of pic Ok, top half stretched with bright line in the centre15V supply missing, replace fuse F601 1A near LOPTx
SharpCA10 51DS02H
no soundIC104 NVM24C16 (RHIX1588BMZZ)
SharpCA10
service modeto enter service mode switch on while holding VOL- and CH+ together
SharpCA10
not memorising customer preferences (col, bright, cont) every time the set switched onthere is no customer preference memory on these sets, alter for optimum in service mode
SharpCA10
no soundaudio Ics muted due to pin 12 being held low, SMD C2310 or C2320 33nF leaky
SharpCA10
No response to R/C or front controlsCheck R704/5 68k but in this case the main micro IC101 C161K had a short on pin 74 data I/P - lifting this pin gave correct amplitude of data across R102. Chip is 80 pin sm device!
SharpCA10
green patches/strange colours (usually on bright scenes)CRT shadowmask warping on excessive beam current. Enter service mode, select page 00 and set POS 04 (brightness) to 24; POS 05 (saturation) to 2C; POS 06 (contrast) to 4B.
SHARPCA10
Dead Secondary voltage was missing . R 713 (560 K ) in series with R 714 (560K) was O/C
SharpCA1 51DT25H
frame collapse, no sound, won't go to stbyno 10V line, replace Q500 BC328


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.