Sharp5BSA 51AT15H
not stopping in tuning, pic distortedcorrupted EEPROM, enter service mode and set AFT to 9F
Sharp5BSA 51AT15H
no teletextIC1001 SDA5254 (RHIX1578BMN1)
Sharp5BSA 51AT15H
No sound/pic & all o/p volts a third down Q509/510 in fop s/c
Sharp5BSA 51AT15H
No sound/pic - goes to st/by aft 30 secsC604/C622 220µ in line dr cct (not C804/822)
Sharp5BSA 51AT15H
No greenEnter service mode (V-, P+ & mains on) to check setting - was set to zero
Sharp5BSA 51AT15H
LOPTr runs hot and goes s/creplace Q602 RHTX0118BMZZ (LOPTr Q601 part no RHTX0132BMZZ)
Sharp5BSA 51AT15H
Lines/chopper tfmr sqealingC804 & C822 220µ in line driver stage
Sharp5BSA 51AT15H
LED pulsing, lack of frame. IntermittentC713 1000uF leaky and Q509 (RHTX0108BMZZ) leaky B/C
SHARP5BSA 51AT15H
LACK OF HEIGHT WITH PATTERN ON SCREENREPLACE C713 1000MFD
Sharp5BSA 51AT15H
lack of height and patterning on the screenC713 1000uF
Sharp5BSA 51AT15H
Int off with screeching causing corruption of AGC & AFC memory settingsQ708 BC338-40 in sw5v - used BD131 as higher powered replacement
Sharp5BSA 51AT15H
Int loss sound and/or colour for 1sec .Change C209 from 1uF to 100nF 50v Pt No VCEAGA1HW104M , C808 from 100nF to 47nF 50v Pt No VCKYTV1HB473K ( use only Sharp part
Sharp5BSA 51AT15H
Int cuts outHT ok, 5volt supply +5Vb low Q708 BC338-40 u/s
Sharp5BSA 51AT15H
HT high at 114v (105v) & EHT varying (can blow BU508DFI (don't fit BU508DF)ZD717 & 718, Q708 (7v supply) faulty
Sharp5BSA 51AT15H
Green LED flashes and dim - no sound/picHT = 113v (should be 105v); Q708 (BC338-40) and D715 (5v1 zener).


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.