SonyKV1975R
INT RED PICTURE, CRT The picture would turn light red and the brightness levelwould drop for about a minute. The tube would snap and the picture wouldreturn to normal.
SonyKV2071R
INT RED PICTURE, CRT The picture on both of these units would turn light red andthe brightness level would drop for about a minute. The tube would thenarc and the picture would go back to normal.
SonyKV2084R
INT RED PICTURE, CRT On both of these units the picture would intermittently turnlight red and the luminance level would drop. This would stay for abouta minute, and then the tube would snap, and the picture would return tonormal.
SonyXR44
RADIO INTERMITTENTLY SHUTS OFF BY ITSELF This unit was intermittently shutting off by itself in theradio function. The solder was not sticking to the diode lead. It wasas though the lead was not clean or had a cold solder connection. Thelead would slip right through the solder connection. H
SonyESR10
RADIO SHUTS OFF BY ITSELF This diode has a cold solder connection or a dirty lead andthe solder will not stick to the lead.
SonyD7S
UNIT WILL NOT PLAY No focus search. This problem may have been caused byservicer after he replaced FOP. L504 was open and there was a soldershort under it which was causing Pins 18 and 20 of IC502 to be shortedtogether.
SonyRME100V
USE OF EDITOR WITH JVC HR-7650U VHS VCR VCR has 10 pin camera jack. Do we make an adapter to inter-face with RME-100V? -HQ COMMENTS: We currently have no adaptors available for VHS VCRYou may however suggest to the customer to contact a video supply outletwhich carries adaptors. The adaptor
SonySLHF1000
TEARING AT TOP AND BOTTOM OF PIX IN BI SLOW AND STILL Tearing at top and bottom of pix in Beta I, slow and stillmode. All other speeds look OK. Tape path also checked good. Ialso seen SL-HF750 -HQ COMMENTS: We have evaluated this unit. A combination of tape path,BI RF switching adj., and slow tracking
SonyKV2780R
HIGH PITCHED SQUEAL (AUDIBLE) ALL THE TIME, REPLACE YOKE Audible high-pitched squeal from inside TV cabinet all thetime. We are beginning to see numerous complaints of high-pitchedsqueal from 27 TV receivers.
SonyKV2093R
PICTURE BOUNCE, REPLACE IF BLOCK After about 15 min. picture would bounce and with the audioreceiving both SAP and MAIN there was a pop in the right channel. Videoin was good. Found this to be heat related as cooling if block unit wouldgo back to normal.
SonyKV25XBR
VERTICAL JITTER ON PAY-PER-VIEW CHANNEL Customer in Chicago subscribing to Group W Cable set experi-ences vertical jitter and roll on Pay-Per-View channel only. All otherbroadcast and pay channels OK. -HQ COMMENTS: Pls compare composite video waveform at Pin 22/IC1501 forOK channels and the
SonyCDP620ES
WILL NOT READ TOC - NOISY FOCUS SEARCH Unit seemed to have a focus servo or search problem. Withscope on FO test point, focus search going up was OK but in focus searchgoing down there seemed to be an open servo loop.
SonyCCDM8U
NEED PART NUMBER FOR CHASSIS ON PAGE 126 Need part number for chassis on page 126. -HQ COMMENTS: The part number is A-7010-080-A. A S/B will be issued.
SonyTCFX510R
INCORRECT DESCRIPTION IN S/M Correct P/N for case, silver should be 3-307-532-31 and forblack one should be 3-307-532-11. -HQ COMMENTS: We will issue a Service Bulletin.
SonySDP505ES
WRONG PART NUMBER IC702 (CXP5016H-118S P/N 8-759-800-54) was ordered from KCP.Received P/N 8-759-800-54 (an LA3365 IC). LA3365 is correct. Micro-processor has incorrect part number.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.