SintomaCausaSoluçãoPor:
SonySLHF400
SNOWY PICTURE IN BETASCAN WHEN WARM (APPROX. 1 HR OF USE) After running the unit for approx. 1 hr, when CUE or REVIEWis used picture is extremely snowy. Unit was very temperature sensitive.
SonyXR77
NO LOADING Cass will not load. This happens on models XR-50, XR-70.and XR-77. 385 deforms with use (years) to the point where loading isincomplete. 387 joint lever assy can latch 386 threading arm assy. Removecass holder, then carefully bend upwards to restore 9
SonyESR10
WRONG PART NUMBER Reference numbers 229 and 230 are crossed. In orderingreverse pinch roller (item 230 on page 26 of service manual), I receivedforward pinch roller (item 229). -HQ COMMENTS: We will issue a S/B.
SonyKPR4110
CP6001 OPEN, REPLACED CP6001 This unit is used with a Panasonic VCR PV-1770 and when theVCR comes out of the scan mode (review) the unit will go into HV shutdownand sometimes open CP-6001. This is caused by a problem with the VCRchanging the horizontal freq. This unit opened CP-60
SonySL5200
INT. BLOWS F001 AND Q002 Unit would very int. blow Q002 and F001. It was very hard tolocate the problem because short would disappear on the 12V line before itcould be located.
SonySLHFR90
SERVO ADJUSTMENTS IN MANUAL INCORRECT Test point for Betascan drum speed adjustment (P. 202) isincorrect. Also, X-0 jitter adjustment is impossible - can -HQ COMMENTS: Correct test point for Betascan adjustment is IC021 Pin 5.X-O jitter adjustment is not necessary due to servo improvement
SonyCDP70
DISPLAY INDICATES ALL ZEROS Display would not function, all zeros displayed at alltimes. All other functions were OK. Inspection revealed no clock pulseson Pin 37, IC106.
SonyCDP203
RF PLL ALIGNMENT CORRECTION Service manual says to adjust L201 for 4.3218 MHz. I believethis to be in error and L201 should be adjusted for 4.2818 MHz. -HQ COMMENTS: You are correct. I will issue a S/B.
SonyEVC8U
NO VIDEO PB 1) Unit had no playback video - just intermittent flashes.2) Poor sync and rainbow in picture.
SonySL5200
COLOR BEAT DURING PLAYBACK WITH AUDIO IN CONNECTED Color beat on monitor only during P/B when audio input isconnected (E-E is OK).
SonyEVS700U
VIDEO DROP-OUTS AFTER REPEATED PLAYBACK Customer complaint: After repeated playback of a section oftape, dropouts develop. 1/4 inch diagnal scratches found near center oftape. Not sure if problem develops during CUE/REV or PAUSE. Unable toduplicate scratch at SSC.
SonyCFS700
WRONG PART # IN S/M Customer says part supplies does not match part in unit. Seeletter from customer. -HQ COMMENTS: The correct P/N for the spring is 4-854-771-00. A S/B wasissued - Tape Recorder #204.
SonyAIR8
SCREW PART # Customer has ordered part twice, and insists that it does notfit. Part # on part matches that in S/M. Is it possible that there is atypo in S/M? Have tried to verify but do not have this model in shop. -HQ COMMENTS: Steve, I checked with KCP. Last s
SonyWM75
NO P/N - PACKING MATERIAL, HEADPHONE JACK No P/N for rubber packing which goes in the headphone jacks. -HQ COMMENTS: P/N is 3-326-140-01. We will issue a S/B.
SonyCFS950
NO P/N - RUBBER GASKET No part number for rubber gasket that fits into (cabinet assy,front) Ref #28. -HQ COMMENTS: This item does not come separately. You must order thecabinet. We have asked Tokyo to provide it in the future.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.