SintomaCausaSoluçãoPor:
SonyBMC550
LITHIUM BATTERY One customer has lost lithium battery already one customerbattery was missing from carton and one wants to purchase replacementjust to be on the safe side.
SonySL2710
UNIT PULSATES BETWEEN RECORD AND PAUSE MODES IN STEADY CYCLE When entering REC, unit would cycle between REC and PAUSE ata rapid frequency. Random pulse at collector of Q517, SS-21 board causedproblem. Q518 was found defective. Replaced Q518, unit OK.
SonyCDXR7
WRONG PART NUMBER Transistors Q1 and Q2 are listed as 8-759-105-29 on page 69of service manual. Correct number is 8-729-105-29. -HQ COMMENTS: We will issue a T/N and S/B.
SonyRM704
RM704 IS NOT AVAILABLE RM-704 is not available. NPC substitute part is RM-708, butshape is not the same. If size and shape is more important to customer,can RM-706 (A-1009-074-A) or RM-705 (not all function) be substitutedsuccessfully? -HQ COMMENTS: As replacement of units
SonyAIR8
DISPLAY MALFUNCTION Low or no audio, all segments of the display come on when astation is received, but display acts normal in scan mode or when unit isnot tuned onto a station, also display blanks out completely in PSB mode.
SonySTRAV460
BACKGROUND NOISE In FM mode after 45 to 90 minutes there is excessive back-ground noise. Also, the sensitivity seems to have decreased. -HQ COMMENTS: If the problem is in the FM, I would suggest you wouldheat-test Q101 RF amp. Also check the transistor mechanically, o
SonyCDX5
NOISE When using a CDX-5, XR-65 and XM-55 and listening to a disc,sound is very clean when listening to either a tape or radio, excessivemotor noise shows up in the system. Though, when bypassing the CDX-5 themotor noise disappears. One dealer has tried as m
SonyKV25XBR
NO RGB OUTPUT Set had no RGB output when unboxed. Scope showed good videoin at IC301 Pin 3 and also Pin 2 but no video out at Pins 32, 33 or 34.A check of supply voltages showed the following: 140 volt line was 130volt. 16 volt line was 15 volt. 8 volt line was 7
SonyBMC110
CORRECTION TO SUPPLEMENT #1 Page 8 Ref. 334 and 338 reversed in Expl. P/N 3-681-404-01(Flange 334) 3-681-410-01 (Nut 338) -HQ COMMENTS: We will issue a T/N and S/B regarding this subject. Thefollowing will be changed. 1) Reverse Reference Balloons 334 and 338.2) Add screw (P/N
SonyKV2675R
NO VIP, LEAKY D-103 No VIP. Noise on M2 data line Pin 28 IC103 A board.Voltage approx. 4.5VDC. When checking M2 line at Pin 14 of IC050 Tboard could see a faint horizontal pulse.
SonyMTL10
REPACK KIT Approx. 3 months after installation of MTL repack kit(T-998-025-81), IC became defective. Only way to get new IC is to consumeentire new repack kit.
SonyKV1992R
INTERMITTENT REMOTE, CORRODED PLUG ON REMOTE MODULE Many complaints on KV-1970, -1971 and -1992 with intermittentremote function.
SonyWM10
WRONG BATTERY LID Two different type battery lids produced for WM-F10 may besame problem as WM-F10 Technical News A-0062 Feb 15, 1985. -HQ COMMENTS: Although both lids are different in color of the sidewall, they are physically compatible and are registered as the samepa
SonyKV2670R
CABLE INTERFERENCE, SUGGEST 220 MHZ TRAP USE TV on cable. Vertical bars channels, K thru W. Per the cablecompany, there is a pilot signal at channel J (220MHz). I have not beenable to get a trap at this frequency (220MHz). -HQ COMMENTS: Please try Microwave Filter Company. The address is6743 K
SonyXR65
FM DRIFT FM would come in with stereo indicator lit when unit was firstturned on. After about 20 minutes stereo LED would go out. Slightlyadjusting RV4 would turn indicator back on for a short time before itdrifted again. Found that by hitting C48 with freeze


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.