Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18940
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKVD2512
Nicam int reverts to mono soundNicam buffer tr Q181 JC501 or 2SC2785
SonyKVC29
No pic - sound, HT, crt htrs all okR807 burn up & change diode in series with it (causing leakage)
SonyKVC252ID
Stuck on chan 00Replace EEPROM IC005 SDA 2546. (24C08 is the same.)
SonyKV-C25/27
Starts on Pr0 and every time Pr+ is depressed, it goes subsequently to Pr8, Pr16,Pr24 and to Pr0.Change D008 5Vzener located near M58655 memory chip.
SonyKV-C25/27
Memory inoperative. Memory chip replacement failed.Check that pin 2 of memory chip is at -30 volts. If not check D809, R830, L807 and the -30V smoothing cap. In two cases, L807 was found to be open cct.
SonyKVB2923E
No pic or LED at sw on - EHT present. On entering a command LED blinks rapidly 3/4 timesPossible CRT low emiss - try decreasing value CRT heater ballast res to check
SonyKVA2942U
Vol intermittentR627 27R hi res
SonyKVA2942S
FOR VERTICAL SHIFT AND HEIGHT PROBLEMSENTER SERVICE MODE AND MAKE SURE "GEOMETRY SET" IS OFF
SonyKVA2932U
Garbled Txt chars briefly at sw on - no menu/textX2001 on M board
SonyKVA2922
TrippingC605 220µ in psu low cap
SonyKVA2542
DEADCHECK CIRCUIT PROTECTORS PS682 AND PS681
SonyKV36FS76U
Sleep timer operates 2 mins too earlyMod req - IC107 pt no 680230304
SonyKV3410B
BU508 blown - getting hot.Check value from supply control ( HT? ) pot to 135v rail , gone high.
SonyKV32WS3U
Faint pic, OSG & sound - menu functs work but no stereo optionEEPROM corrupted - reset data & mod (sorry no info on doing this!)
SonyKV32DX30U
When replacing LOPTxDon't use pt no listed in manual - wrecks crt - use Part No 145330841.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads