SonyKV29X1
INT BLANK SCREENREPLACE A BOARD
SonyKV29LS30
Dead - LED flashes 11 timesLOPTr BU2515DX s/c - dry joints line dr trfmr
SonyKV29FL1U
Tripping with LOPTr Q802 s/cDry joints R816 1k 3w & around line dr trfmr
SonyKV29F3U
To enter service modepress following buttons on remote slowly in sequence + (osd button), 5, vol+, TV and it will switch on in test mode 1 press menu on the remote next--power off to quit
SonyKV29F2
SET COMES ON WITH FLYBACK LINES THEN GOES DEADREPLACE Q707 (GREEN) Q710 (BLUE) OR Q704 (RED)
SONYKV29F2
NO SOUND FROM COLDREPLACE IC3 WITH PREPROGRAMMED NEW TYPE
SonyKV29F1U
TrippingStops when 71v sec supply dis'd. Q603 2SC3502 in prot cct leaky
SonyKV2964MT
Dead - no st/byAvalanche diode R2K s/c, STRS5941, & caps in pri psu 10µ 400v, 2µ2 350v, 47µ 63v & check for dry joints
SonyKV28WS2U BE3D
St/by LED flashes twiceM24C32 sm EEPROM replaced (caused by crt flashover?)
SonyKV28WS2U BE3D
Service mode enteringfrom st/by press OSD/5/volume+/tv; TT____ will appear top right. Entering TT38 sets the TV as a 28 inch, TT24 sets TV as PAL I, TT79 for widescreen. MENU gives submenu choices eg geometry; TT00 exits & stores
SonyKV28NX1U
blows LOPTr DJ on L803
SonyKV28LS35U
Reverts to st/by aft initial rush of EHT, LED blinks twiceOver-current error caused by R618 270k in current sensing hi res
SonyKV28DS60U
Lack of widthPS1502 1A cct prot on D1 LH vert panel (now upgraded to 2A)
SonyKV28DS60U
Electronic Screwdriver settingsWith set in st/by, press r/c in order - "display", "5", "Vol+", "TV" - the screen now displays " T T - -". Select "Menu" puts you into service mode
SonyKV27XSC
No start upPri chopper tfmr o/c


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.