SonyBE-3B KVX2182U
drop-out on one audio channel, may loose one channel completelystereo decoder IC201 TDA2822M (875950221)
SonyBE3B KVX2182
Tries to start with burst of EHT then reverts to st/by with LED perm litInsul washer on FOP chip (shorting -15v line to chassis)
SonyBE-3B KVX2102U
dead, no start upR600 39k 5W in PSU (1-216-490-11)
SonyBE3B KV28FX20U
DeadTNY253P IC5605 P/N 875958419 osc/chopper IC, TLP721 IC5606 P/N 874901321 4 pin opto, 10uf 450V C5658, 0.47ohm fusible R5602
SonyBE3B KV28FS0U
E/W dist & int widthDry joints connector CN800 for int width - R835 27R 3w o/c for no E/W
SonyBE-3B KV25T1U
dead, no start upR600 39k 5W in PSU (1-216-490-11)
SonyBE3B KV25T1U
No pic, sound & EHT OKR824 1k8 burnt & C815 dry joints
SonyBE3B KV24WSIU
LED flashes 6 times at sw on - no actioncould be memory problem (IC701) or dry joints tuner/multiway block connecting tuner pcb
SonyBE3B KV24WS1U
White horizonzal bars, crackling sound, led blinking sometimes 6-7 or 13 times, stuck in sbyPin 15 (earth conn) on prescalar chip TSA 5511 or 5512 dry jointed
SonyBE-3B
lack of width - no EWcct prot PS801 ICPF10 o/c
SonyBE-3B
int no chan change & sounddry joints IC001, 002, RA2, 3
SonyBE3B
LINE PULLING ON MACRO TAPESREPLACE JUMPER WIRE JW802 , MOUNTED IN LOC L800 with ( 330R ) 3W res PtNo 121590821
SonyBE3B
GOES TO STBY AFTER REPLACING IC605 7812REPLACE WITH ORIGINAL TYPE ICMCT7812CT Pt No. 8-759-279-76
SonyBE3B
Clicking noise during Nicam receptionTV02794R
SonyBE3B
All supply lines come up then go low ( StBy )Check pin 9 CN001 if high set in protection mode disconnect pin if set still fails to come on Replace IC002 Memory chip PtN


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.