SonyAE2 KVE2533E
LED blinks 13 times at sw onFrame drive chip was the cause aft replacing FOP chip & still having same symptoms
SonyAE2 KVE2532U
Poor sync, mosaic & odd colsDig comb filter
SonyAE-2
To disable prot lineremove pin 1 marked "PROT" on µ pcb
SonyAE-2
shuts down with BLED flashing 13 timesfield fault indication - but was R895 18k sm o/c which monitors line fb pulses
SonyAE2
Won't come out of st/by - intField o/p chip TDA8179
SonyAE2
Vertical ripple with staining effectD613 double diode in psu has leak in one leg
SonyAE2
vertical ripple & 'staining' effectD613 - double diode in psu leaky
SonyAE2
Trips to st/by aft 2 secs - points to field faultReplace field chip & R854 0R47 as no -15v supplies were present
SonyAE2
Trips 13 times - indicates field faultSTB9379 field chip - can use TDA8179S??
SonyAE2
Sound missingR627 27R fusible o/c brought back dist sound - IC261 TDA2052 faulty causing uneven supply volts
SonyAE2
Sound cuts out when vol turned upD/J on X1101 crystal on Nicam PCB
SonyAE2
Shuts down aft 30 secs then sw back on aft few mins then repeats sequence - no leds litHT measured 61v (st/by mode) - st/by 5v to micro low at 0.7v. Cct prot PS681 int high res (On board A near front adj to board D)
SonyAE2
Set will only display one station if another is seEAROM ( ST24C16 ) Data corrupted replace & set up
SonyAE2
Set comes on then collapses into lines in the centCheck H.T. for 119V if low at 70V Q613 IN AUDIO PROTECTION CCT Pt No 8-729-216-22
SonyAE2
RANDOM SPIKES AND DIST. HIGH SOUND LEFT SPEAKERADD 3K3 RES AND 0.015mfd CAP PARALLEL TOC201


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.