SonyAE-1A KVD2912U
burring on audio on switch on for a few minsC615 1000uF 25V
SonyAE-1A KVD2512U
sound cuts out from cold, distorted when warmC615 1000uF 25V
SonyAE1A
USER DEFINED SECURITY CODE IS UNKNOWNWHEN CODE IS ASKED FOR - PRESS "TEST" ON A SERVICE
SonyAE1A
Sound takes more than a min to arriveC615 1000µ 25v in 14v supply - feeds audio mute cct
SonyAE1A
Int reverts to st/by - due to high HT of 175v (135v)R522 100k in HT sensing cct
SonyAE1A
Field lin poorC531 680µ 25v
SonyAE1A
Field - partial collapseC531 680µ 25v
SonyAE1 series
Powers up then sw off with apparent 3 - 4 flashes of LEDNot an error code but merely psu attempting to start. Try replacing C611, C633, C636, C605, C608, C615 and C622. Also check R522 (100K ohm).
SonyAE-1 KVX25TU
blank screen, no sound, may be int.DJ Q608 12V regulator
SonyAE1 KVX2542Y
Field o/p chip has short lifeLOPTx faulty - gives excess 27 volts supply (32v)
SonyAE1 KVM2901E
Slow start up from coldCheck C605 (220µF/35V), C617 (100µF/50V), D617 in the start up circuit along with C605 (220µ).
SonyAE1 KVM2511U
When adj HTMake sure you adj correct preset - the one near FOP chip - NOT the st/by HT one in psu
SonyAE-1 KVDX271TU
takes 10-20 min to come onC615 1000uF 35V
SonyAE1 KVDX271TU
Shuts down at sw on with burst of EHTIC251 audio chip cracked & dry joints - caused by incorrect conn of ext amp - also check C615 1000u 35v for dry joints
SonyAE1 KV211XMTU
Dead - dry joints scan coil plugThen excess width unable to adj - Replaced L806 (shorted turns) in the East/West circuit (just behind the LOPTX).


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.