Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Sony | CDXC510 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CDXC410 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CDX71RF | PART AVAILABILITY: HIDEAWAY/WIRED DISPLAY | The manual has no part number for Hideaway units and WiredDisplays that are defective and cannot be repaired to component level. | ||
Sony | CDX65RF | PART AVAILABILITY: HIDEAWAY/WIRED DISPLAY | The manual has no part number for Hideaway units and WiredDisplays that are defective and cannot be repaired to component level. | ||
Sony | CDX51RF | PART AVAILABILITY: HIDEAWAY/COMMANDERS | The manual has no part number for Hideaway units and Wiredcommanders that are defective and cannot be repaired to component | ||
Sony | CDX5090 | DISPLAY INDICATOR BAD (FOUND POOR SOLDER ON CNP801) | The CDX5090 had a bad display readout. This was caused by abad solder connection on CNP801. This connector is located on the displayboard. | ||
Sony | CDX45RF | PART AVAILABILITY: HIDEAWAY/COMMANDERS | The manual has no part number for Hideaway units and Wiredcommanders that are defective and cannot be repaired to component level. | ||
Sony | CDX4090 | LIGHTS ON DISPLAY WENT OUT | The Display board lamps (ref# PL801, PL802) went out, foundthe Display board resistors (R825,R827) were over-dissipated. Thiscaused the Display board to become damaged. | ||
Sony | CDX3100 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CDX2100 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CCDV701 | NO RECORD, LOOKS LIKE ONE CHANNEL BAD (FOUND Q202 DEFECTIVE) | No record, looks like one head out. Found pin 4 of HR10board good. At pin 24 of IC001 (on the HR10 board) the signal was good,but bad at pin 37. Found Q202 to test pin 204 shorted. | ||
Sony | CCDTR91 | NO FOCUS, NO ZOOM (FOUND PS501 OPEN) | Unit has no focus or zoom functions. | ||
Sony | CCDTR7 | NO E-E VIDEO (REPAIRED OPEN TRACE BETWEEN R217 & D303 CATH.) | No E-E video burst and sync ok. | ||
Sony | CCDTR65 | NO PB VIDEO (FOUND IC158 ON VS100 MCB BAD) | No PB video audio OK. Camera E-E OK. | ||
Sony | CCDTR5 | DISTORTED EVF PIX; EE OK (FOUND Q230 ON VS-22 MCB DEFECTIVE) | EVF pix extremely distorted EE pix ok. |