Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CFD540 | TEST MODE | CD will not go into test mode by shorting TP CD Test.Shorting 3.67vdc to ground prevents power switch S813 from turning on. | ||
Sony | CFD520 | TEST MODE | CD will not go into test mode by shorting TP CD Test.Shorting 3.67vdc to ground prevents power switch S813 from turning on. | ||
Sony | CFD510 | UNIT DEAD - REPLACE FUSE | Unit dead, shield covering CDB not soldered to board andshorts out Q305 and blows fuse. This is third unit with same problem | ||
Sony | CFD30 | IC201 KEEPS GOING OUT | Unit came in with IC201 out. Servicer replaced andreturned to customer. Customer returned unit with IC out again. Servicerreplaced again and it played for three hours and went out again. Whenoperating all voltages on IC are normal and there is no r | ||
Sony | CFD250 | OPTICAL BLOCK REPLACEMENT | When replacing optical block for this model the 884824601listed in manual is shipped. This part will not connect to thetranslation board item 651. I have found after research that SB 332 whichis for the CFD580/757/758/767/768 lists the translation boar | ||
Sony | CFD21 | NO INTERMITTENT PICK UP CD | Excessive lock tite applied to head azimuth adjustingscrew. This glue spills over to tape sensor. Tape sensor is for end oftape. 2% of problems this model. | ||
Sony | CFD12 | NO AUDIO - (SHORT CIRCUIT) | The jumper resistor (no ref in SM) shorts groundingjumper J800 and causes fusible resistor R310 to open repeatedly. | ||
Sony | CFD10 | CD WILL WORK SOME TIMES - RESOLDER IC703 | Cd will work intermittently, IC703 has cold solder or nosolder. Unit will focus but not spin sending the optics on the outposition. | ||
Sony | CFD10 | CD WON'T WORK | Replaced melted cd lid, melted by high power lamp? and foundref 113 magnet holder shrunken also. Replaced ref 113 part number338697101 listed in manual and it won't fit properly, still too short. | ||
Sony | CF610 | MOTOR M702 DOES NOT ALIGN WITH BOARD | Turntable ass'y motor M702, does not align with CD motorcircuit board. If motor is re-positioned in turntable, the motor contactstill do not line with holes on circuit board. | ||
Sony | CCEDF30 | R234 ON INCORRECT LAND | Replaced SS86 board and the symptom was no autofocus. Techfound no AF on pin 5 of IC200, 51. Pin 26 input auto/manual would switchbetween 51-0v also pin 1 & 2 of IC200 5V. | ||
Sony | SLV940HF | DISTORTED PITURE | Playback distorted picture. | ||
Sony | SLV940HF | PIX UNSTABLE ON SELF RECORDED PB (B/W VERTICAL BARS)-IC351 | Pix is unstable in PB self recordings (will go to B/W bars). | ||
Sony | SLV780HF | NO HIFI AUDIO - BAD CONNECTION AT CN103 ON HF34 BOARD | No hifi audio. | ||
Sony | SLV780HF | WON'T PLAY - REPLACED T LOADING GEAR AND MAIN SLIDER | Won't play. |