SintomaCausaSoluçãoPor:
SonyCDPCA8ES
RANDOM SKIPPING - ADD RTV SEALANT BETWEEN SPINDLE MOTOR & BD The unit will skip once every one or two hours when testedusing the Sony skip checker jig. Replaced the optical block, BD board,Spindle motor, sled motor, and assoc gears and flex cables also replacedthe DSP IC301, System control IC501, and installed th
SonyCDPC445
DRAWER NOT OPENING
SonyCDPC445
LOADING PROBLEM Unit would not load correctly. Sled motor would not stop when it reached limit. Limit switch closing and closure being sensed by the Servo/IC101. System control CPU/IC501 did not recognize limit switch closure due to
SonyCDPC345
WHISTLING NOISE Re: Vistain's complaint of whistling noise with this unit.
SonyCDPC265
DISTORTED AUDIO - REPLACED IC501 ON MAIN BOARD After a few minutes the aduio would be distorted on both channels.
SonyCDP261
DRAWER WON'T OPEN - SOLDERED ON LEAD OF JW45 Drawer won't open due to no VCC on IC204. Also found no +7 volts on pin 22 of cnp101.
SonyLANC JIG
NO RM-95 EMULATION We had a LANC jig that simply did not perform properly.There was no RM95 emulation and the jig would never detect a camera.After performing the modification the jig worked, but the RM95 emulationwas temperamental. The waveform adjustment did not have
SonyXRU880
NO AUDIO (FOUND C306 AND C308 HAD LEAKED) No audio from tape deck. C306/308 standard electrolyticcapacitors leaked onto EQ board. Traces aaround C306 were corroded andphysically lifted off the board. Electrolyte seeped through feedthroughs and stained the mechanism. All feed through are blac
SonyXRU700
ERRATIC TAPE DECK OPERATION (FOUND ROTARY SLIDE SWITCH BAD) Tape would load in steps then eject. Very erratic movementof tape transport.
SonyXRU330
DEAD (FOUND C102 HAD LEAKED, CAUSING DAMAGE TO 5V TRACE) Unit dead. Found 5V line to IC201 pins 3/4 at 2.5v.Discovered C102 leaked and corroded a trace.
SonyXRU220
DEAD (FOUND LEAKING C102 CAUSED DAMAGE TO 5V LINE) Unit dead. Found 5V line to IC201 pins 3/4 at 2/5v.Discovered C102 leaked and corroded trace.
SonyXM2042
INTERMITTENT AUDIO, FOUND BROKEN SOLDER CONNECTIONS ON JACKS Line input jacks create cold solder connections due tovibration and handling/installing/removal of RCA jack. These jacks seemto be supported by main board only. Factory installed small pieces ofrubber for support, but they fail.
SonyMDXU1
GEAR REF. 310 GRINDS DURING LOAD, DAMAGES GEAR TEETH. Gear ref. # 310 grinds during load, causing the teeth to getchewed up. FPR P3402 states to replace the gear. Discovered that geargets ground up because of poor solder on SW621 (loading-end detect switch)causing loading motor to run too long.
SonyCDXC490
ERRATIC OPERATION FROM KEY SWITCHES, FOUND OPEN GROUND TRACE All key switches function wrong. Examples: Select buttonwould turn unit off AM would switch FM function presets at wronglocations.
SonyCDX600DSP
NOISE IN AUDIO, MAY NOT PLAY AT ALL IF EXTENSION CABLE USED When using the extension cable for troubleshooting the CDmechanism, static noise may be heard in the audio. Sometimes, the unitwill not play a disc at all, or the disc may be ejected while beingplayed. -SOLUTION (found by K. Budoff): Removing C309 from


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.