Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Sony | CDX5490 | DISPLAY FAILURES (MISSING SEGMENTS, CRACKED LCD, ETC.) | Various display failures have been noted, such as missingsegments, cracked LCD, segments always illuminated, etc. | ||
Sony | CDX5470 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | CDX5470 | ERROR CODE E44 | Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er | ||
Sony | CDX5470 | DEAD (REPLACED C502 AND C531) | Unit would not power up. | ||
Sony | CDX5460 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | CDX5460 | ERROR CODE E44 | Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er | ||
Sony | CDX5290 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | CDX5290 | ERROR CODE E44 | Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er | ||
Sony | CDX5290 | DISPLAY FAILURES (MISSING SEGMENTS, CRACKED LCD, ETC.) | Various display failures have been noted, such as missingsegments, cracked LCD, segments always illuminated, etc. | ||
Sony | CDX5270 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | CDX5270 | ERROR CODE E44 | Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er | ||
Sony | CDX5270 | SKIPS WHEN CAR IS MOVING (REPLACED BROKEN DAMPER SHAFT) | CD skips when car turns corners, shifts gears or anyirregular motion. Found one of the damper shafts broken (ref. 117)causing optical chassis assy's (ref. 157) suspension to be uneven. Thisresults in skipping all the time. | ||
Sony | CDX5260 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | CDX51RF | PART INCOMPATIBILITY (RF MODEL): LOWER CASE/SPRING ARM ASSY | Different size pivot point for arm spring assy onCDX51RF/71RF. Lower case for CDX51/71 will not work on RF model armspring assy's. | ||
Sony | CDX51 | DOES NOT READ DISCS (FOUND RETAINER SCREW HAD FALLEN OUT) | The unit would not read discs. |