SonyXR7500
UNIT LOCKS UP If power is removed when tape is playing the unit locks upwhen power is re-applied (no function or button will work). M901, Q301, &IC501 have been replaced. Manual reset will not clear problem. Pressingthe OFF button or lifting the handle before turni
SonySTRAV970X
R-975 REPLACEMENT PART NO LONGER AVAILABLE Service bulletin HFP0320 calls for replacing R-975 with a partnumber 1-214-848-00. There are none available from Kansas City Parts,while there are 22 backordered for Kansas City Parts. They show noarrival date and the REPL column now shows a replacemen
SonySTRAV970X
SCHEMATIC ERRORS - VOLTAGES AROUND IC202 ARE INCORRECT The voltages on IC-202 are not correct. Pin 21 shows 5vdc andis going to pin 4 of IC-201 which shows 0vdc but it goes to pin 24 ofIC-101 on the display board which shows 5vdc. Also pins 51 through 61 areshown as 0vdc but pin 53 goes to Q-205-E which sh
SonyEVC3
PAUSE AND SCAN BRIGHT AND WASHED OUT. ADJUST RV801 1VP-P Unit played fine in scan and pause (jog mode). Picture toobright.
SonyTCC5
TRAY WILL NOT MOVE INTO PLAY POSITION - REPOSITION TRAY Door closes but tray does not move into Play position. Fiveseconds later door will reopen. Door switch is good.
SonyTCC5
DRUM WILL NOT LINE UP IN THE RIGHT POSITION, DRUM AND D891 Drum will not line up in the right position. Spins and stopsbetween cassette holders then starts spinning again and stops betweencassette holders and so on.
SonyCFD440
CD NOT FUNCTIONING - REPLACE D-701, P/N 8-719-911-19 No mechanism motion. D-701 opens, dropping 2 1/2 volts acrossit. I repaired only the CD section and of the ones I repaired about twoout of 20 have this problem.
SonyD180K
DEFECTIVE BACK LIGHT - REPLACE PL-901, P/N 1-518-585-11 The LED's behind the play mode, key mode and stop buttons arevery dim. Checked voltages on Q-901 and they were fine. Checked PL-901and voltages were off slightly. Disconnected PL-901 and LED's were fine.PL-901 was drawing too much current. Applies to
SonyCDPC325
POPPING NOISE WHEN AMS BUTTON IS PRESSED (R-375 NOT MOUNTED) Popping noise heard when AMS button is pressed in rightspeaker and sometimes distorted audio. Checked the inputs of IC-306 andfound pin 4 had incorrect voltage. Upon diagnosis of input circuit Ifound R-375 to be missing. Also applies to serial number
SonyCDPC425
POPPING NOISE WHEN AMS BUTTON IS PRESSED (R-375 NOT MOUNTED) Popping noise heard when AMS button is pressed in rightspeaker, and sometimes distorted audio. Checked the inputs of IC-306 andfound pin 4 had incorrect voltage. Upon diagnosis of input circuit Ifound R-375 to be missing. Also applies to serial number
SonyTCW31
NO AUDIO OUT ON DECK "B" - IC501 FAULTY, 8-759-601-06 Incorrect voltage at pins 12 and 13 of the selector, IC-303.Upon diagnosis of IC-501, found pin 1 remaining high after unsoldering.Also applies to serial number 8807705.
SonyMZ1
UNIT DISPLAYS "HOLD" (CN-803 NOT CONNECTED) Unit would not load disk. Unit displays Hold. CN-803 wasunplugged.
SonyMZ1
NO POWER WITH AC ADAPTER (NICAD BATTERY OK); PS-401 OPEN Unit had no power with adapter, but worked ok with battery.
SonyMZ1
INTERMITTENTLY WON'T ACCEPT MO DISCS (REPLACE REF. # 108) When trying to load a recordable disk, the unit will eject thedisc immediately. It sometimes accepts disc with unit upside down. Foundpin 66 of IC-801 jumping high but not going back low as recordable discwas inserted. All three units loaded pre-recor
SonyCCDTR101
NO OPERATION WITH RM-95 (PERFORM SB CAM0112 IMPROVEMENT) Customer's RM-95 does not operate her camcorder. It also doesnot operate a CCD-TR81. Does service bulletin number CAM0112 apply tothese models? this RM-95 will not work on any camcorder with a regulatedLanc DC of 5.6V. The reset IC in the RM-95 is no


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.