Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | MDP510 | WILL NOT PLAY DISCS | Spindle motor will not turn focus error in on PS-193 ok. | ||
Sony | KV27XBR10 | PICTURE BLANKS ON IN-ACTIVE STATIONS, REPLACED D-303 | Picture would blank if you tuned to an in-active station. | ||
Sony | KV27XBR15 | SHUTDOWN WITH CRT CONNECTED | With CRT connected set would shut down. With CRT disconnectedset would operate. | ||
Sony | KV32XBR15 | AUDIO BALANCE WAS COMPLETELY TO THE RIGHT, REPLACED IC-102 | When set turned on, audio balance always was completely to theright. Reset balance and set was ok until power was turned off. Thenbalance was always to right on turn on. | ||
Sony | ITK500 | RADIO AUDIO ON SPEAKERPHONE | When you press the speakerphone, the radio audio would bleedin. | ||
Sony | ITA600 | ICM TAPES BEING EATEN AND AUDIO FLUCTUATION ON PLAYBACK | ICM message tapes were being eaten and curled up on the top1/4 of the tape. When it did play, the audio fluctuated. | ||
Sony | SPP80 | NO MICROPHONE AUDIO FROM BASE WHEN USING SPEAKERPHONE | Intermittent microphone audio output could be heard in handsetfrom base when using speakerphone by flexing PCB or hitting unit lightlyon top, but audio would soon be lost. | ||
Sony | ITA850 | INTERMITTENT ICM WILL NOT OPERATE - SOMETIMES OGM WON'T | Reel sensor won't count intermittently, thus shutting down ICMtape mostly but also sometimes the OGM. Problem is during manufacturing.Bracket (Part No. 112) somehow was made that when IC PCB No. 906 fits intoNo. 112, there is space for movement between | ||
Sony | ITA750 | INTERMITTENT ICM WILL NOT OPERATE - SOMETIMES OGM WON'T | Reel sensor won't count intermittently, thus shutting down ICMtape mostly, but also sometimes the OGM. Problem is during manufacturing.Bracket (Part No. 112) somehow was made that when IC PCB No. 906 fits intoNo. 112, there is space for movement between | ||
Sony | STRD2020 | MAJOR OUTPUT FAILURE - NO OPERATION | Both units have the same failure shorted Q-702, 703, 704,705, 706, 707, 708, 709, 710. Defective IC-701, and open F-902. Alsoapplies to serial number 801035. Have not been able to determine whychannels are being wiped. We have noted poor and open sol | ||
Sony | CDP470 | UNIT READS OUT NO DISC AND STOPS PLAYING | After playing a few discs, unit would read out no disc, cool-ing IC-4 brought back operation. | ||
Sony | TCDD3 | INTERMITTANT HEADPHONE JACK | Headphone connection is intermittant. I found the internalconnections had loosened from repeated insertion and removal of phones. -HQ COMMENTS: I opened the unit and removed the headphone jack. Iremoved the three sections of the J-303 and adjusted the | ||
Sony | RM762 | AFTER MEMORIZING CAN NO LONGER OPERATE TV, SEE TVP SB # 89 | Customer has a cable box which uses an infrared remotecontrol. He programs his cable box commands into the Sony remote, he thenproceeds to pull up the Guide Menu on his TV. After getting into theGuide Menu, he could not access the different guide selec | ||
Sony | SPP115 | CANNOT PUT HANDSET IN TEST MODE | The procedure in the service manual on putting the handset inthe test mode does not work. -HQ COMMENTS: Tokyo fax (T91032). The correct procedure for putting thehandset in test mode is as follows. 1. Put unit in RINGER ON mode.2. Press Talk while holdi | ||
Sony | WMD3 | INTERMITTENT OUTPUT FROM HEADPHONES OR LINE OUT | Intermittent output from line out or headphone out. Flexingcircuit board would show problem better. |