Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Sony | ITD250 | ERROR IN THE SERVICE MANUAL | The frequency of oscillation of the crystal X1 is listed inthe service manual as 300 KHZ. However, the reading on the crystal is800 KHZ. -HQ COMMENTS: The service manual is in error. The correct frequency is800 KHZ. Thanks for the info. | ||
Sony | ITD150 | ERROR IN THE SERVICE MANUAL | The frequency of oscillation of the crystal X1 is listed as300 KHZ in the service manual. However, the reading on the crystal is 800KHZ. -HQ COMMENTS: The correct frequency is 800 KHZ. The manual is in error.Thanks for the info. | ||
Sony | KV32XBR65 | HORIZONTAL RGB LINES IN TOP PORTION OF PICTURE, R-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV32XBR50 | HOR. RGB LINES IN TOP PORTION OF PICTURE, REPLACED R-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV32XBR15 | HORIZONTAL RGB LINES IN TOP PORTION OF PIX, REPLACED R-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV32XBR10 | HORIZONTAL RGB LINES ON TOP OF PICTURE, REPLACED R-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV27XBR65 | HORIZONTAL RGB LINES IN TOP PORTION OF PIX, SEE SB # 76 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV27XBR60 | HORIZONTAL RGB LINES IN TOP PORTION OF PICTURE, SEE SB # 76 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV27XBR50 | HOR. RGB LINES IN TOP PORTION OF PICTURE, REPLACED R-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | KV27XBR15 | HOR. RGB LINES IN TOP PORTION OF PICTURE, REPLACED R-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. Normally, adjusting the REFfunction in the service mode will shift the lines out of the picture area.However, in this case the shift was not enough. | ||
Sony | CCDF45 | NO VIDEO | IC-202 had input but no output. Pin 14 0v, pin 12-15-18, 4.5vwhich is high. | ||
Sony | TAAX401 | INTERMITTENT LOSS OF AUDIO/UNIT APPEARS DEAD | Customer complaint of No Power. On bench unit workednormally until main PCB was flexed slightly. When flexed, audio on bothchannels would go out and the front panel appeared as if unit was off. | ||
Sony | CCDTR5 | NO Y OUT OF CAMERA (ONLY COLOR) | Customer complains picture is a negative in viewfinder.Found it has no Y. | ||
Sony | CCDTR5 | NO COLOR RECORDING | Camera REC in black and white. Plays pre-recorded tape ok. | ||
Sony | SL2500 | NO AUDIO ERASE | While recording, no audio is erased and video may also have arainbow effect. TP-502 measured 45 to 60 vp-p and Q-544 had 5vdc oncollector. Q-542 base 1.7vdc emitter 12vdc collector approximately 5vdc. |