SonyS3900
CASSETTE DECK NOT ACCESSED VIA REMOTE The remote control does not access the cassette deck(TCW295). Sales literature indicates that it would.
SonyKV27XBR10
HORIZONTAL OFF FREQ, HUE SHIFTED TO GREEN, REPLACED IC-301 Horizontal was locked with blanking bar six inches from right.Also color was green. Adjustment would not bring into correct position.
SonyPVM2530
PART NUMBER MISSING FOR CP COMPONENTS Need part numbers for all CP packs on (11-A) board. Also needpart number for D-2325 which is shown on the actual PC board but not onthe schematic or board diagram. -HQ COMMENTS: Please refer to service manual correction No. 4.
SonyCDXR66
INCOMPATIBILITY OF NEW MD SLED CHASSIS AND OLD CHUCK PLATE When you order X-3320-567-1 MD Sled Chassis Assembly, itsubstitutes to X-3320-567-2. When installed, unit will not clampcorrectly. I found when ordering chuck plate (5) (Ref. No.261) itsubstitutes to new part number 3-348-558-01. It will clamp correct
SonyCDXR88
INCOMPATIBILITY OF NEW MD SLED CHASSIS AND OLD CHUCK PLATE When you order X-3320-567-1 MD Sled Chassis Assembly, itsubstitutes to X-3320-567-2. When installed, unit will not clampcorrectly. I found when ordering chuck plate (5) (Ref. No.261) itsubstitutes to new part number 3-348-558-01. It will clamp correct
SonyCDXR77
PART NUMBER MISSING Original service manual shows C-701 as (1-163-059-00).01uF 50V chip capacitor on page 47. The schematic shows that it is a.22F 5.5V capacitor. Investigation revealed that the part number forC-701 should be 1-125-486-11.
SonyCDP370
CDP-370 WILL NOT PLAY OR LOAD CDP-370 would load but would not play. Then the drawer wouldopen but would not close when open/close button was pushed. I also founda voltage discrepancy on IC-6, pin 50. The manual says it should be 8volts but is is 22 volts.
SonyTCWR710
DECK (A) NO FUNCTION Unit would not go into Play. Pressing Play would cause unitto go into Fast Forward, Rewind or nothing at all.
SonyWMF100III
INCORRECT SHIPMENT OF PARTS When you order reference number 109 (P/N 3-329-737-01), youget reference number 133 (P/N 3-329-736-01). Are the part numbersreversed in the service manual or has the stock been mixed up? -HQ COMMENTS: I checked with Kansas City Parts on this and they f
SonyWMF100II
INCORRECT SHIPMENT OF PARTS When you order reference number 75 (P/N 3-329-736-01), you getreference number 84 (P/N 3-329-737-01). Are the part numbers reversed inthe service manual or has the stock been mixed up? -HQ COMMENTS: Thanks for sending this information to us.
SonySTJX380
WILL NOT HOLD CHANNELS IN MEMORY OR LOCK ON TO A CHANNEL This tuner would not hold channels in memory or lock on to achannel.
SonyGEN-VID
TAPE SKEW AROUND ACE ASSEMBLY Capstan wears causing tape skew around the ace assembly. Iwas wondering if it was possible to get just the capstan instead of thewhole motor in hopes of making units more economical to repair?
SonyD9
SPINS BUT WILL NOT READ TOC There is a black plastic and copper shield glued to the top ofthe processing ICs on the main board. Noticed that the ground connectionwas missing. Added jumper to ground and checked ok. Apparently, theungrounded shield was acting more like an antenna.
SonyCDPC10
NO RESET BUTTON On page 5 of the service manual, in both the laser checkprocedure and the troubleshooting flow chart, there is mention of a resetbutton, while none exists in the unit. -HQ COMMENTS: Thanks for the info. There is no reset button as younoted. To reset t
SonyXR6500
REW/FF KNOB FALLS OFF I have had three customers call that have this unit that com-plain that the FF/REW knob comes off when they pull it to perform FF/REW.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.