SonyKV36FV15
AA-1
RASTER KV36FV15 Unit will turn on with the front panel control but the set will not develop raster or sound. The high voltage will turn but no raster. After 3 minutes the raster and sound will appear Tech needs to look into the Data & Clock lines of the chassis. These lines must be 5 volts peak to peak and have a typical word length of 1000 milli seconds. Tech discovered the SDA pulses were 3.3 volts peak to peak whereas the CLK pulses were at 5 volts. Tech had to isolate each load on the SDA line and found the PIP tuner was responsible for loading down the DATA line. Muller
SonyKV32XBR250
AA-1
Noise Video Sony KV32XBR50 This customer has a Goldstar 8mm/VHS dual deck VCR located under this television on the built in shelf. When customer uses the 8mm deck the playback of the tape has corrupted audio, and poor tracking performance when played back on this television The design of the 8mm format is significantly different from that of the VHS. The 8MM format does not have any stationary heads and completely relies on the signals from the rotary video heads on drum. 4 ATF (Auto Tracking Fix) carriers are recorded on to the tape. Apparently the shielding in the 8 mm VCR, this close proximity to the TV, and the lack of shielding in the Sony TV caused the corruption of the 4 ATF signals. Placing the VCR on the bottom shelf of the TV cabinet corrected the symptom. Muller
SonyKV32XBR85
AA-1
NO RASTER KV32XBR85 Unit has no raster. Has sound and weak OSD. Stand-by light is not flashing. Unit appears to have a normal IK feed back to the jungle IC. Screen voltages are 670 vdc and the cathode is running at 180 vdc. Unit looks like a defective Jungle IC. Replacing the Jungle IC corected the symptom. Muller
SonyKV32XBR37
AA-1
NO RASTER KV32XBR37 serial 80139945. Unit has no raster. Has sound, CRT filaments, and high voltage. Led in front is flashing Tech may have a IK failure. When bringing up the G2 the raster will appear with full vertical sweep and a purple screen. Not much green. Tech needs to look at the IK buffer collectors on Q771, Q772, & Q773. Normally with beam current there shall be about 1 volt on each collector. With the CRT Socket removed all collectors must drop to ""0"" volts. Q771 did not. It was 1.2 volts regardless if the tube was connected or not. Tech needs to short Q771(E&B) and see if the collector will drop. It did not. TV will need a replacement Q771. Replacement cured the symptom. ""Muller
SonyKV32TW77
AA-1
No high voltage Sony AA-1 chassis. Unit no high voltage or sound. RY602 latched at turn on. Tech replaced the flyback and Q601, Q602, VDR601, VDR602, VDR603 & R607. After theses components were replaced the unit still did not produce secondary B+. Only 3 volts on the collector of the Horizontal output. Inspected the Power oscillator and discovered that it was running and producing 167 volts DC at the input side of RY602, but a <13 volts on the low side. Jumping RY602 restored High voltage. Unit had a bad RY602 relay in the power supply. Muller
SonyKV32XBR45
AA-1
GEOMETRY Unit is trying to constantly adjust the vertical height and horizontal size intermittently. When monitoring the E/W Pin output of the M board the signal was very instable. It was decided to replace IC351 the Jungle IC. This corrected the trouble. Muller
SonyKV32TS46
AA-1
dead Unit was dead. has shorted horizontal output and shorted Q601, & Q602 components in power supply replaced. After replacement unit will turn on but still has no secondary voltage output of power transformer. All relays click but no high voltage. Has sound. Tech needs to check the condition or RY602. RY602 is the switching relay that turn on and off the set. The relay is ""HOT"" switched. In other words one side of the relay is connected to power oscillator output that runs nearly 350 vac Peak to Peak at 90Khz. Once the relay is closed this energy is placed across the power output transformer and provides the drive necessary to produce the B+.Measuring the input voltage of the relay to ""HOT' ground found it to be 150 volts DC mode. But on the other side of relay we has 3 volts DC mode. Unit has defective RY602 relay. ""Muller
SonyKV32XBR45
AA-1
CONVERGENCE Unit has nis-convergence of red & blue vertical lines which are displaced horizontally. Tech replaced the CRT. This did not solve the problem. Suggest tech look for R789 and see if it is open It is on the on ""C"" board. The value is around 10 meg. There are two different chassis and CRTs used for this model. If they have the older chassis type that requires H stat convergence (CRT board has H stat control) they need to order the older CRT as per the manual. If newer type (No H stat) then the new CRT as per Service Manual supplement -1 is needed. CRT 8733-743-05 The H Stat is done using the Yoke ring magnets. ""Muller
SonyKV32XBR45
AA-1
CONVERGENCE Unit has mis-convergence of red and blue vertical lines. They are displace horizontally. Tech replaced the CRT without correcting the symptom. R789 open H-state not operational. What I'm finding is a resistor that appears to be open on this ""C"" board It is R789 The value cannot be read nor is it listed in the ESI software parts list. Trying another value from 10 to 20 megohms. This resistor is in the ground return of the H-stat resistor that is installed in the CRT. Tech needs to try different values to try and make this set converge horizontally. This TV converged with a 10 megohm resistor. ""Muller
SonyKV32XBR45
AA-1
CONVERGENCE KV32XBR45 Unit has sever Horizontal static convergence error. TV cae to us from another shop where the CRT and flyback was replaced. Customer call us for secont opinion. Suggest tech look for R789 and see if it is open It is on the on ""C"" board. It The value is around 10 meg. There are two different chassis and CRTs used for this model. If they have the older chassis type that requires H stat convergence (CRT board has H stat control) I have attached the two Service Manual supplements, and the SB325R1. However none of them have show this resistor. We were able to install a resistor in this unit that was a two 10 megs in series. Trimming the value by adding another 10 meg in parallel with one of the other 10 megs. we were able to converge the set. Original part was not available. ""Muller
SonyKV32XBR45
AA-1
CONVERGENCE KV32XBR45 Unit has convergence of all vertical lines are displace horizontally. Tech replaced the CRT without authorization. This did not solve the symptom Suggest tech look for R789 and see if it is open It is on the on ""C"" board. It The value is around 10 meg. There are two different chassis and CRTs used for this model. If they have the older chassis type that requires H stat convergence (CRT board has H stat control) they need to order the older CRT as per the manual. If newer type (No H stat) then the new CRT as per Service Manual supplement -1 is needed. CRT 8-733-743-05 The H Stat is done using the Yoke ring magnets. I have attached the two Service Manual supplements, and the SB325R1. ""Muller
SonyKV32XBR45
AA-1
CONVERGENCE KV32XBR45 convergence is way off in the horizontal direction Unit has an open R789 a 18 meg 1/2 watt resistor for the Horizontal static convergence. The tech will have to make a resistor out of 3, 6.2 meg resistors. Muller
SonyKV32XBR45
AA-1
CONVERGENCE KV32XBR45 convergence is way off in the horizontal direction Unit has an open R789 a 18 meg 1/2 watt resistor for the Horizontal static convergence. The tech will have to make a resistor out of 3, 6.2 meg resistors. Muller
SONYKV21FS105
BA-5
Não atua a tecla power.Trocar r 1033 de 22k para 15k (SMD) está ligada ao pino 14 do IC1001. Placa lateral.joaomvjr
SONYKV 29FS100
So aparece brilho no modo Esporte nos outros = TELA ESCURAR547 (330r) aberto, seguir pino 2 do Flay BackCONTINUACAO DA LINHA DO ABL.Mauriílio


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads