Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18945
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKV1975R
HORIZ. OUTPUT TRANSISTOR SHORTS, REPLACE HDT T501 The horiz. output transistor short about every two weeks.Found the drive to it to be incorrect. Replacement of the drivetransformer resolved the problem.
SonyKV2645R
NO PIC/SOUND, REPLACED D511, R533 AND L510 The unit had no picture or sound. We found D511/15V rect. tobe shorted and R533 open. The problem was not resolved until L510 wasreplaced, which probably precipitated the problem. -HQ COMMENTS: L510 is off flyback in 15V line circuit.
SonyCCDV110
NEED CORRECT PART # IC306 Part number in the manual is incorrect. Part in unit issurface mount IC. Part ordered is PCB mount. -HQ COMMENTS: The correct part # is 8-759-937-56.
SonyKV25XBR
HUM IN AUDIO WITH SUPER IMPOSED VIDEO When writing appears on existing picture, it's hums loudly.
SonySLHF400
UNIT INTERMITTENTLY THREADS The cassette intermittently would not seat all the way downduring loading. This of course did not permit the unit to thread. Wefound the guide plate #230 to be improperly position (see illustration)therefore the cassette would sometimes hang up on it.
SonySLHF1000
WAVING IN PB Customer is experiencing a waving effect during playback. -HQ COMMENTS: SL-HF1000 can exhibit waving for a few reasons. Theflying erase heads protrude slightly farther out than the video heads.This can cause some waving if a thin tape is used. Suggest
SonyFD42A
KEYSTONE, REPLACED D602 Unit had keystone problem, traced problem to base of regulatorQ602. Had a 5Vpp (mostly negative) waveform, nothing at collector.Found diode D602 open, not clamping negative half of waveform.
SonyCCDM7U
NEED PART NO. FOR MICROPHONE WINDSCREEN P/N for windscreen? -HQ COMMENTS: P/N is X-2536-710-1.
SonyHVM302
IRIS NOT FUNCTIONING No video output except when iris is manually opened.
SonyTCWR530
NO RECORD The unit would not record. We found the problem to be causedby a shorted trimmer cap in the bias osc. circuit, C312.
SonyCDP203
INTERMITTENT SHUFFLE PLAY OR ERRATIC OPERATION We have had several units at the SSC with the complaint oferratic operation or intermittently they will enter shuffle play. Theproblem is associated with a cold solder joint on R809 which is acrossthe master control clock crystal.
SonyKV25XBR
RETRACE LINES The unit operated fine except that on some NBC programs therewould be a 2 to 3 retrace lines on the top of the screen. All othernetworks/channels worked fine and it was only certain programs that wereaffected on NBC (ie, Price is Right, sections of even
SonyICF2010
INTERMITTENT OPERATION OR NO AM Several units with a defective X3 crystal. They exhibit thefollowing symptoms: 1) No AM, FM works fine, display works OK 2) Unitappears to have a locked up UPC. May not be able to turn the display offwith the power switch. AM does not work. FM may
SonyPSLX5
INTERMITTENT MOTOR ROTATION The unit would intermittently not start up or would shut offduring play.
SonyKV2080R
SNOWY PICTURE ON #8 AND 10, REPLACED ANT BLOCK The set had a snowy picture on channels 8 and 10 only. Allother channels worked fine. We found the problem to be the antennaswitch block.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.