Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18945
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyD7
NO PLAY Unit would spin up at turn on but would not play disc. Uponstarting unit with no disc spindle motor would spin up but would alsosurge at rate related to focus search. All pins on IC502 and IC503 lookednormal except for Pin 10 (SP). Batt indicator was
SonyKV2024AEB
SOUND BUZZ, NO COLOR - REPLACE Q008 & IC203 Unit had buzz and loss of color. Found Q008 shorted, thisrestored the color and also switched the 4.5MC audio line whereby I hadaudio with buzz. Replaced IC203 and this restored full audio with nobuzz. Set OK. Difficult problem to resolve due to the
SonyCDP70
UNIT SCRATCHES COMPACT DISC WHILE PLAYING One of three supporting pins does not go down intermittently,when disc is in for play. Also rubbing the disc gently while playing.It does not affect any playing disc. Ten of customers new discs haveround scratches in the middle of circumference. Event
SonySLHF900
P/N FOR 16 CONDUCTOR CABLE FROM JG-2 TO CH-38 BOARD Refering to Page 167 of S/M, we need the 16 pin cable fromthe JG-2 board to the CH-38 board. Please advise. -HQ COMMENTS: The cable is not available as a replacement part. I will,however, send you a cable from another unit. In the future, please hard
SonyMPKM8
NO PART # FOR CABLE Need part # for cable - page 17. -HQ COMMENTS: This part is not presently available. We will check withTokyo and inform you of availability.
SonyCCDM8U
P/N No part number in manual for several springs used in gripass -HQ COMMENTS: Please refer to Supplement 2 Page 78 Ref. No. 69 (nextto 68) P/N 3-695-457-01, Ref. No. 93 (below 66) P/N 3-695-766-01,Ref. No. 98 (to the left of 70) P/N 3-303-890-01.
SonyCCDM8U
NO CAPSTAN FG, DEFECTIVE FG GENERATOR Found 3 or 4 units with no capstan FG signal. Can FG genera-tor be replaced separately? -HQ COMMENTS: The FG generator is not available separately. Pleaseorder the complete capstan motor.
SonySL5000
BLUE LINE 1" FROM BOTTOM OF PICTURE DURING SELF-REC PLAYBACK Pre-recorded tapes OK. Adjusted servo system - no help. -HQ COMMENTS: Please check Page 15 of SL-5000 Troubleshooting Guide(Servo Control - Picture not Normal at Self-Rec and Playback) and informof results.
SonySLHFR70
P/N SUBSTITUTION FOR RY-5 BOARD RY-5 board. Subs to 99109934 (no longer usable for service).RPC shows A-6711-601-A as P/N for RY-5 board. Please confirm. -HQ COMMENTS: Correct P/N is A-6711-656-A.
SonySLHF300
NO PART NUMBER No part number listed for item directly below Ref. #272(P. 117 of S/M). This is the base of the AC head assembly. -HQ COMMENTS: P/N requested is X-3684-319-1. This number is correctlylisted in the SL-HF500 Service Manual.
SonyXR20
OUTPUT IC IC found in unit was part #1-806-655-11, TA7240AP. And wassupposed to be 1-806-655-11 according to manual. Unit made in Taiwan.Two IC's are not same physical size, so cannot be interchanged on PC bd.
SonySLHF600
NO POWER, OR PICTURE ROLLS DURING PLAYBACK Will not power up, or pix rolls while playing a tape.
SonyITA600
TRANSFER FROM HANDSET TO SPEAKER PHONE If you pick up the receiver to make a call, you will hang upthe phone if you go to speaker phone. Is there any way to modify oroperate the unit so you do not hang up when going from hand set tospeaker phone. -HQ COMMENTS: The IT-A600 is not designed to
SonyKV25XBR
SET COULD BE TURNED ON/OFF, NO OTHER FUNCTIONS Set could be turned on or off, no other functions. RGB lightalways on. I found no vertical pulse present in order to system controlto function. Inspection revealed no pulse coming out of IC501, Pin 12.DC voltage at Pin 13 was 0. Cause of problem was
SonySLHFR70
NO RECORD Open print between C60 and R70 on the RY-5 board. Have seenthis a few times. Board shows no sign of cracks.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.