SonyAE2
Int cuts out & eventually reverts to st/by with LED flashing 13 times (field fault, X ray prot or excess current 135v rail)Fault in excess current cct on board D where D620 int o/c 1N4148 used as replacement
SonyAE2
Front led flashing 13 times, frame problemsReplaced the frame IC TDA8179 with a STV9379, O/c 0.47ohm res pin 7 FBT neg 15 volt supply to the output chip.
SonyAE2
Field rollingIC501TDA2595/V9 pin 9 field pulse has noise superimposed on it - working at 60Hz - chip faulty - pt no 8-759-513-48
SonyAE2
Field non lin bands/lines across screenIC561 CXD2018Q 48 pin sm chip faulty on panel M
SonyAE2
FAILURE OF VERT OUT IC 1501REPLACE TDA8179S WITH STV9379 8-759-192-71 , AND CHANGE C1506 1-130-777-00
SonyAE2
Dead - Q601 BUZ91A chopper s/cCheck R610 180k, R604 150k
SonyAE2
Cuts out: goes into protection mode: RGB lights edD/J on IC1501 Field output IC
SonyAE2
Chopper TR Q601 s/c ( BUZ91A ) f.e.t.Check R604 ( 150K ) & R610 ( 180K )
SonyAE2
"Txt not available" message on screen & menu screens shifted to rightR38 750k or IC101 SDA5248-5C1 Txt dec chip pt no 8-759-166-41 on Txt pcb o/c
SonyAE-1C KVX2952U
flyback lines on the topC532 100uF 50V
SonyAE-1C KVX2952U
dead, chopper Tr s/cC611 47uF 50V, Q602 872920902
SonyAE-1C KVX2942U
very weak sound (as if in mute)D271 13v zener (8-719-921-88) o/c in the PSU
SonyAE-1C KVX2942U
OSD wobbles int from side to side, set switches offresolder 12V regulator under plastic chassis
SonyAE-1C KVX2552U
int switch on/deadresolder IC604 located under plastic chassis assy
SonyAE-1C KVX2552U
int colourreplace trimmer CT332, short pin 11 of IC331 TDA4510 and adjust trimmer CT332 for near stationary colour


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.