Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18945
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyAE1
EW FAULT+RH SCREEN BLANKDRY JOINTS ON AV BOARD!
SonyAE1
Dead with flash & fizzing noiseSpark from T601 power trnsfmr when powered with variac - dry joints on winding conns on trnsfmr pins 17 & 18
SonyAE1
Dead - st/by light comes on brieflyRunning on dummy load not recommended - LOPTx u/s
SonyAE1
Dead - PS601 2A cct prot o/cNo reason found for its demise but replace C615 1000µ 25v as a precaution
SonyAE1
Dead - mains fuse o/c, Q602 2SD1548LB chopper tr s/cD608 RU-3AM s/c also check R614 220R 10w dry joints
SonyAE1
Dead - comes on in st/by if sw on from sktCheck for 0v at pins 2 & 3 of IC601; if pin 3 = +7v sus LOPTx. Earth pin 3 and check for smoke!
SonyAE1
DeadR1603 2R7 7w o/c; Chopper tr 2SD1548 s/c; R614 220R stand up res dry joints
SonyAE1
Crackle on soundD/J around earth points check mains bridge
SonyAE1
CHOPPER TRANSISTOR SCR614 OC MAYBE IC601 ALSO TEA2164
SonyAE1
Chans won't store - intThe -30v supply to IC003 M58655 Memory chip falls to -15v. L807 feed coil was int o/c
SonyAE1
CAN'T STORE STATIONS PIN 2 ICOO3 NOT -33vL807 OC PtNo 140750400 also check R008 C017
SonyAE1
Burning smellDry joints R614 - can fit in alternative posn; check R611 & L607 for o/c
SonyAE1
Blank screen, no tuning memory when heatedMemory chip IC003 (M58655P) used in AE1 chassis requires -30V on pin 2 to operate. If -30V is lost, no station memory - check L807 for o/c in LOP when warm. L807 used as voltage dropper to reduce volts derived from transformer & its inductance (10mH) is important. It should always be replaced with original part, otherwise damage will occur - part no 1-407-504-00.
SonyAE1
Blank screen with flyback linesR805 ( 1R2 ) o/c
Sony27XRTU
NO SYNC NO INPUT AT PIN 5 IC501 NO VIDEO OUTPUT ATSAA5230 US CHECK Q002 12v REG


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads