Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDTR94 | EATS TAPES (FOUND TENSION SPRING, REF. 781, HAD COME LOOSE) | Unit eats tapes. Found problem to be caused by tension spring,ref. 781, coming loose. | ||
Sony | CCDTR94 | DEAD (FOUND POOR SOLDERING ON CN003 ON DD-80 MCB) | Unit was dead (would not even eject). Found problem to becaused by poor soldering of CN003 on the DD-80 MCB. | ||
Sony | CCDTR94 | EJECTS IMMEDIATELY AFTER LOADING (REF # 752 WAS DISLODGED) | Immediately after loading a tape, the unit would eject thetape. Found that the exit guide, ref. # 752, had come out of the track. | ||
Sony | CCDTR94 | WON'T LOAD TAPE (FOUND DRUM WOULD NOT ROTATE; REPLACED DRUM) | Unit would not load tape. Found that the drum had a tightspot which prevented it from rotating. | ||
Sony | CCDTR94 | NO REW OR REVIEW, NOISE IN PLAY (MAGNET ON REEL CAME LOOSE) | The unit had no rewind or review. Noise could be heard duringplay. Found problem to be caused by the magnet on the supply reel comingloose. | ||
Sony | CCDTR94 | DEAD (FOUND LOOSE CONNECTOR BETWEEN POWER MCB & MAIN MCB) | The unit was dead found a loose connector between the powerboard and the main board. | ||
Sony | CCDTR94 | WON'T STAY IN RECORD (FOUND MODE SWITCH IN WRONG POSITION) | Unit would not stay in record when the start/stop button waspressed. Found that the start/stop mode select switch was set in theposition which allows recordings to be made only while the start/stopswitch is held in. This is an operational feature of th | ||
Sony | CCDTR94 | DEAD (FOUND BATTERY CONTACT J001 ON DD-80 MCB COLD SOLDERED) | Dead. Found battery contact J001 on DD-80 MCB was coldsoldered. | ||
Sony | CCDTR94 | NO THREAD, NO EJECT (FOUND HIGH TENSION, REF 769 WAS LOOSE) | Unit would not thread tape. Found problem to be caused byratchet tension spring (ref. 769) coming dislodged from at the chassisend. | ||
Sony | CCDTR84 | NO PIX IN EVF, ONLY VERTICAL LINE (FOUND BAD SOLDER ON L903) | EVF had no horizontal scanning, resulting in only a verticalline displayed. Problem was found to be caused by bad solder on L903 onthe VF-102 board. | ||
Sony | CCDTR84 | DOOR WON'T CLOSE (MODE SWITCH BAD, MECH DID NOT EJECT FULLY) | Cassette door would not close, because the mechanism did notfully eject the last time the tape was ejected. Found problem to becaused by a faulty mode switch. | ||
Sony | CCDTR84 | NO EJECT (FOUND TENSION REG. REF 833 WAS JAMMIMG LS CHASSIS) | The unit would not eject the tape. Found problem to be causedby the tension regulator plate which had come loose and was jamming the LSchassis. | ||
Sony | CCDTR84 | NP FF OR REW (FOUND TEAR IN FP249) | The unit would not rewind or fast forward. Found problem tobe caused by unit not sensing movement of the supply reel. This wascaused by a bad conection on FP249, caused by some sort of contact with asharp edge. | ||
Sony | CCDTR84 | POOR FOCUS ON EVF (FOUND FOCUS RING ON CRT MOUNTED POORLY) | The unit had poor focus on EVF. Found problem to be caused bythe focus ring being hot-glued to the CRT at an angle which preventedgood focus. This apparentlt occurred during manufacturing. | ||
Sony | CCDTR84 | NO ZOOM (FOUND TAB WHICH FOLLOWS WORM GEAR DISLODGED) | Lens would not zoom. After removing the zoom motor found thatthe inner tab which follows the worm gear on the motor shaft had twisted,preventing proper engagement with the worm gear. |