Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDTR54 | INTERMITTENT NO POWER (FOUND COLD SOLDER ON J1 ON DD-80 MCB) | Unit was intermittently dead. Found problem to be caused bycold solder on J1 of the DD-80 MCB. | ||
Sony | CCDTR54 | EJECTS AFTER TRYING TO LOAD (REF 771 WAS JAMMED ON REF 752) | After trying to load (with or without a tape) the unit wouldgo to eject mode. Problem was found to be caused by the pinch rollerassy, ref. 771, slipping over the base of the take-up guide assy., ref.752, causing these 2 parts to jam with each other. | ||
Sony | CCDTR54 | EATS TAPES (FOUND TG4, REF. 765, WAS BENT) | Unit would eat tapes. Found problem to be caused by TG4, ref.765, being bent. | ||
Sony | CCDTR54 | NO POWER IN CAM MODE (FOUND DD-80 CN003 LOOSE FROM VC-167) | Unit had no power in camera mode. Problem was caused by CN003of the DD-80 board which had come loose from the VC-167 board. | ||
Sony | CCDTR54 | LINES THROUGH PICTURE (FOUND POOR SOLDERING OF IC201) | Customer complaint was lines through picture found camerapicture wad distorted. Problem was found to be caused by IC201 on theVC-167 MCB, which was poorly soldered. IC201 is the Y/C processor. | ||
Sony | CCDTR54 | DEAD (FOUND LOOSE CONNECTIONS AROUND IC400) | Unit was dead. Problem was found to be caused by looseconnections around IC400 on the VC-167 MCB. | ||
Sony | CCDTR54 | NO EJECT (FOUND SOLDER BRIDGE ON FP249 SHORTING SENSOR H002) | Unit would not eject. Found problem to be caused by a solderbridge on FP-249 (below the takeup reel). The bridge shorted reelhall sensor H002, preventing any reel pulses from being generated. | ||
Sony | CCDTR54 | EATS TAPES (FOUND TESNSION SPRING, REF. 783 HAD COME LOOSE) | Unit eats tape. Problem was found to be caused by tensionspring ref. 783, which had come loose. | ||
Sony | CCDTR54 | EATS TAPES (FOUND TENSION SPRING, REF. 781, HAD COME LOOSE) | Unit eats tapes. Found problem to be caused by tension spring,ref. 781, coming loose. | ||
Sony | CCDTR54 | DEAD (FOUND POOR SOLDERING ON CN003 ON DD-80 MCB) | Unit was dead (would not even eject). Found problem to becaused by poor soldering of CN003 on the DD-80 MCB. | ||
Sony | CCDTR54 | EJECTS IMMEDIATELY AFTER LOADING (REF # 752 WAS DISLODGED) | Immediately after loading a tape, the unit would eject thetape. Found that the exit guide, ref. # 752, had come out of the track. | ||
Sony | CCDTR54 | WON'T LOAD TAPE (FOUND DRUM WOULD NOT ROTATE; REPLACED DRUM) | Unit would not load tape. Found that the drum had a tightspot which prevented it from rotating. | ||
Sony | CCDTR54 | NO REW OR REVIEW, NOISE IN PLAY (MAGNET ON REEL CAME LOOSE) | The unit had no rewind or review. Noise could be heard duringplay. Found problem to be caused by the magnet on the supply reel comingloose. | ||
Sony | CCDTR54 | DEAD (FOUND LOOSE CONNECTOR BETWEEN POWER MCB & MAIN MCB) | The unit was dead found a loose connector between the powerboard and the main board. | ||
Sony | CCDTR54 | WON'T STAY IN RECORD (FOUND MODE SWITCH IN WRONG POSITION) | Unit would not stay in record when the start/stop button waspressed. Found that the start/stop mode select switch was set in theposition which allows recordings to be made only while the start/stopswitch is held in. This is an operational feature of th |