Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDTR44 | LINES THROUGH PICTURE (FOUND POOR SOLDERING OF IC201) | Customer complaint was lines through picture found camerapicture wad distorted. Problem was found to be caused by IC201 on theVC-167 MCB, which was poorly soldered. IC201 is the Y/C processor. | ||
Sony | CCDTR44 | DEAD (FOUND LOOSE CONNECTIONS AROUND IC400) | Unit was dead. Problem was found to be caused by looseconnections around IC400 on the VC-167 MCB. | ||
Sony | CCDTR44 | NO EJECT (FOUND SOLDER BRIDGE ON FP249 SHORTING SENSOR H002) | Unit would not eject. Found problem to be caused by a solderbridge on FP-249 (below the takeup reel). The bridge shorted reelhall sensor H002, preventing any reel pulses from being generated. | ||
Sony | CCDTR44 | EATS TAPES (FOUND TESNSION SPRING, REF. 783 HAD COME LOOSE) | Unit eats tape. Problem was found to be caused by tensionspring ref. 783, which had come loose. | ||
Sony | CCDTR44 | EATS TAPES (FOUND TENSION SPRING, REF. 781, HAD COME LOOSE) | Unit eats tapes. Found problem to be caused by tension spring,ref. 781, coming loose. | ||
Sony | CCDTR44 | DEAD (FOUND POOR SOLDERING ON CN003 ON DD-80 MCB) | Unit was dead (would not even eject). Found problem to becaused by poor soldering of CN003 on the DD-80 MCB. | ||
Sony | CCDTR44 | EJECTS IMMEDIATELY AFTER LOADING (REF # 752 WAS DISLODGED) | Immediately after loading a tape, the unit would eject thetape. Found that the exit guide, ref. # 752, had come out of the track. | ||
Sony | CCDTR44 | WON'T LOAD TAPE (FOUND DRUM WOULD NOT ROTATE; REPLACED DRUM) | Unit would not load tape. Found that the drum had a tightspot which prevented it from rotating. | ||
Sony | CCDTR44 | NO REW OR REVIEW, NOISE IN PLAY (MAGNET ON REEL CAME LOOSE) | The unit had no rewind or review. Noise could be heard duringplay. Found problem to be caused by the magnet on the supply reel comingloose. | ||
Sony | CCDTR44 | DEAD (FOUND LOOSE CONNECTOR BETWEEN POWER MCB & MAIN MCB) | The unit was dead found a loose connector between the powerboard and the main board. | ||
Sony | CCDTR44 | WON'T STAY IN RECORD (FOUND MODE SWITCH IN WRONG POSITION) | Unit would not stay in record when the start/stop button waspressed. Found that the start/stop mode select switch was set in theposition which allows recordings to be made only while the start/stopswitch is held in. This is an operational feature of th | ||
Sony | CCDTR44 | DEAD (FOUND BATTERY CONTACT J001 ON DD-80 MCB COLD SOLDERED) | Dead. Found battery contact J001 on DD-80 MCB was coldsoldered. | ||
Sony | CCDTR44 | WON'T THREAD (FOUND HIGH TAPE TENSION DUE TO REF 769 LOOSE) | Unit would not thread tape. Found problem to be caused byratchet tension spring (ref. 769) coming dislodged from at the chassisend. | ||
Sony | CCDTR400 | INT. DEAD, SHUT DOWN, LOCKUP (FOUND BAD SOLDER ON CN203) | An ASC reported that the unit had intermittent functions, orwould shutdown or lock up. Problem was found to be caused by poor solderon CN203. | ||
Sony | CPD17SF2 | DEFECTIVE HORIZONTAL OUTPUT TRANSISTOR Q507 | 3 units came in with same problem, defective horizontaloutput transistor Q507 872982107. |