Dicas Reparação SONY




Modelo - Chassis


Pesquisa: SONY Enviar Dica Resolvida
Resultados 18945
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKP53V45
RA2
audio KP53V45 No audio. While in the process of servicing the set the unit lost Green and blue have lost convergence. Unit has a defective PS401 fuse and IC403 in the output stage. As for the convergence problem there is a loose connection between the ""A"" board an the ""G"" ""Muller
SonyKP53V45
RA2
arcing KP53V45 Unit has red tube that is arcing. Tech calling in for Red CRT Approval. CRT is Arcing in the Neck. Muller
SonyKP53S65
RA2
A.C. HUM Sony KP53S65. Cust has two complaints. 1. Unit has low level AC hum when using an external amp connected to the variable/fixed or the monitor outputs of the television. The hum is present when the volume on the TV is muted or set to minimum, and the volume of the external is turned up 20%. The hum is quite noticeable at this level. 2. When using the variable/fixed outputs the set will not have left channel output. I had tech disconnect all connections (except to the variable/fixed output) to the rear of the set while in the condition mentioned in the first complaint. After all other inputs to the set was disconnected the CATV connection was the only connection remaining. When it was disconnected the hum disappeared. This indicated the trouble is caused by a ""Ground Loop"" This condition is caused by the CATV ground is a different potential than the rest of the equipment. This may not be able to be corrected without an electrician checking the customer electrical neutral and ground connections in the customer house wiring. We can simply solve the trouble by having the CATV company installing a ""ground breaker"" in series with the CATV feed. 2. The no output to the left channel output is caused by a torn trace at the left output connector for the variable/fixed outputs. ""Muller
SonyKP46S25
RA1
wrong color The picture turns a reddish or pinkish cast after 20 minutes This is intermittent. Pix flashes upside down then back to normal. This takes about 20 minutes but can be accelerated by heating the IC301 with a heat gun. defective Jungle IC chip IC301 Muller
SonyKP46S25
RA1
verticalPix flashes upside down then back to normal. This take defective Jungle ic301?. Muller
SonyKP53S15
RA1
smear KP53S15 Unit has a green smear When tapping on green CRT the picture the picture will smear. Tapping Muller
SonyKP53V35
RA1
SHUTSDOWN Sony KP53V35 RA-1. Unit shut down as soon as set is turned on. Tech ordered R865 and D814 because they were shorted After parts were installed a new symptom was evident. ""Unit turns on but enters shutdown after the tube warm up. CRT's get bright with ret ""Unit had torn trace on E board that connects the 200 vdc line to CN708(7) which connects to the CR board. Apparently the traces were accidentally torn in the process of moving the chassis around. Repairing the traces corrected the symptom. Muller
SonyKP61XBR48
RA1
shutdown KP61XBR45 9034307 Unit turns on but goes into shut down after raster comes on and the set has a bright screen with retrace lines. Unit now has all three CRT burnedMeasuring the 200 VDC source the finds no voltage, Unit has open R859. Unit will need modification listed in bulletin 291R1 and 281R1 Tech will need to correct the main problem then after corrected the CRT will have to be Muller
SonyKP61V35
RA1
shutdown KP61V35. Unit will turn on then go into immediate shut down Tech has tried all the normal methods of isolating CRT, HV block, Loss of horizontal or vertical sweep disconnecting the 200 vdc source voltage from the red CRT. All these circuits being disconnected still did not prevent shut down.. However the unit will still shut off right after high voltage comes up. I needed tech to check the more of the not so common shut down sensors. These were D board protect line CN1757(7) , ""E"" board Protect line CN851(5), and the ""A: board protect line CN222(4) I first had tech remove the CRT sockets from each CRT to prevent phosphor burns on the tubes. Next remove the fuses on the ""D"" board and remove connector CN1757. Then turn on the television. It turned on with high voltage and stayed on. This indicated the trouble was din the ""D"" board. A quick static test of all the post regulators IC1804(1), IC1803(1), IC1808(1), & IC1807(1) found that a short circuit to ground was indicating on the output of IC1804(1) this is the +5 volt regulator. checking through the board and lifting the bypass electrolytic capacitors on this line discovered a shorted C1832 a 330 mfd @ 16vdc ""Muller
SonyKP53V35
RA1
SHUTDOWN Sony KP53V35. Unit goes into an immediate shut down. Unit will not turn on at all. Unit will try to turn on but shuts off. I had tech measure the B+ at the +135 and the -135 VDC sources. The -135 was not indicating any voltage. There is a 18 ohm short to ground on the emitter of the horizontal output transistor. I'm having tech check into the Horizontal pin amp and horizontal output transistor. If a short in this circuit occur when the set ha a picture it is very likely that CRT damage has occurred. It is recommended the screen be removed or use what ever method available to check the CRT faceplates for phosphor burns. If burned the CRT will also need replacement. Q510 and Q509 shorted Muller
SonyKP61XBR45
RA1
shut down Unit turns on but goes into shut down after raster comes on and the set has a bright screen with retrace lines. Unit now has all three CRT burnedMeasuring the 200 VDC source the finds no voltage, Unit has open R859. Unit will need modification listed in bulletin 291R1 and 281R1 Tech will need to correct the main problem then after corrected the CRT will have to be Muller
SonyKP53XBR45
RA1
shut down Unit had two CRT's Red and Blue leaked on the original ""E"" board prompting their replacement. After changing the CRT's and the ""E"" board it was discovered the set had a symptom of immediate shut down. ""When checking IC901(1&13) and IC903(13) we had no positive voltages that would cause a high voltage protect shut down. At no time did we ever get high voltage or Horizontal drive, for the High voltage output, Q801. However Q505, the horizontal driver for the horizontal output always had drive to it. When the first technician replaced the original circuit board it was discovered that he did not transfer the jumpers on CN804. There must be three jumpers on this connector otherwise the set will never get high voltage. CN804(1&2), CN804(3&4), CN804(5&6). Unit needs these three jumpers to route the 2 ABL circuits, .Horizontal drive pulse. Replacing these jumpers restored Muller
SonyKP53XBR45
RA1
SCREEN Sony KP53XBR45 Unit has a streak across the top of the screen Appears like the unit has a defective screen, or a scratch between the Lenticular and fresnel lens. Tech calling in for an authorization for screen replacement. The defect as the tech explains showed up as a straight horizontal line at the top of the screen. It was a discoloration toward the color yellow when White is displayed. Also on the lower corner was a dark circular pattern that did not match the curvature of the Fresnel lens. I instructed the tech to inspect the entire optical light path for any defects. Tech reported back to me the mirror had a smear completely across the surface area. Possibly caused by a previous cleaning with a cleaning rag that has some oil based contaminate. Gently cleaning the mirror corrected the fault. Muller
SonyKP41T15
RA1
RASTER KP41T15 Unit is turning on. Timer light flashes at turn on and set will have sound, but no raster. Unit has no high voltage. ""E"" board is wet from glycol coolant leak from the Red and Blue CRT's that are leaking Red an Blue tube ""Muller
SonyKP61XBR48
RA1
RAINBOW Sony KP61XBR48. Unit has rainbow colors in the lower right hand corner & when the power turned off using the power button on the television the set will not shut off. Rainbow caused by the speaker wire casting a shadow in the light path from the projected image. Tech needs to reroute wire. Next tech will need to install a 2.2 mfd capacitor across the power switch. Muller


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads