Dicas Reparação Sony







Pesquisa: Sony

Resultados 18974

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyXR4157TAPE STICKS WHEN EJECTING Tapes are intermittently sticking inside when ejected. Thereturn link has a square bend on the end toward the rear of the deck andan angular bend on the front. If the spring is installed backwards, itcauses the problem. -HQ COMMENTS: Thanks for the inf
SonyXR4147TAPE STICKS WHEN EJECTING
SonySLV575DEFECTIVE CASSETTE BASKET (RELEASE ARM) The release arm located on the right side of the loadingcassette mechanism comes off track.
SonyCDP209ESEF BALANCE ADJUSTMENT Service manual shows EF balance and adjustment procedure, butdoes not give adjustment pot etc. Laser PU is preadjusted at factory andis not field adjustable. Service manual is in error.
SonyCDPC800PART NUMBER NOT LISTED FOR CHASSIS There is no part number listed for the Chassis Assembly, shownon page 27 of the S/M. It is listed as NOT SUPPLIED. Do I have toreplace this unit to resolve this problem? -HQ COMMENTS: Let me see if I can get a part number for this.To Tokyo: Can you su
SonyKV27TS22PICTURE GETS DARKER ON LEFT SIDE, REPLACE V OUT IC-501 Picture is dark on left side of screen and progressivelydarker toward the edge. It becomes more pronounced as unit warms up andapproaches approximately two inches from left to right. The symptom canbest be seen using the color bar pattern in which case
SonyCCDF33NO CAMERA VIDEO AFTER 15 SECONDS No camera video after 15 seconds. The iris would close after15 seconds and would not re-open.
SonyCCDV4NO CAMERA VIDEO AFTER WARM-UP After five minutes camera video would go out, audio was fine.
SonyKV4000NO BAND SELECT, FAULTY BAND SELECT SW S901 No band select. The unit stays in the low band mode eventhough a flicker can be seen on the screen and a click in the audiowhen the band select button is depressed, band switching does not occur.
SonyEDV9500INCORRECT ALIGNMENT PROCEDURES/EDV-9500 SERVICE INFORMATION The AFC adjustment in the alignment instructions is incorrect. RV-001 controls the delay of the HDW signal, not the WHD. Since the VCOreset pulse generator is synchronized to the HDW in variable speed,playback if this adjustment is not set correctly fla
SonyXS6940PART NUMBER FOR SPEAKERS (CAR STEREO) Need part number for speaker assembly for XS-417 and XS-6940.Computer says exchange but also says finished goods not avail fromNPC. What do we do with these if they are in-warranty orout-of-warranty? It would help if we could get a list of part numbers
SonyXS417PART NUMBER FOR SPEAKERS (CAR STEREO) Need part number for speaker assembly for XS-417 and XS-6940.Computer says exchange but also says finished goods not avail. fromNPC. What do we do with these if they are in-warranty orout-of-warranty? It would help if we could get a list of part number
SonyCCDV8AFUNO POWER UP OF CAMERA SECTION Camera section would not power up. Found DC-DC converter bad.Replaced DC-DC converter camera would power up for just a second then shutdown. Measured 5 volt line with Ohm meter (5 line measured 4 Ohms toground). Traced it down to shorted C-741 on ME-1
SonySPP110REPLACED BASE MOTHER BOARD AND ID TRANSMISSION DID NOT WORK Order a brand new board to replace the one that customer haddrink spilled on. First board is broken near the AC adaptor andtelephone jack due to poor wrapping. Tried a second one, could not resetID code between base and handset. Reordered the third bo
SonyPVM1910QPICTURE TEARS HORIZONTALLY Picture would tear horizontally. Adjusting HorizontalOscillator would not help. Vertical was ok. -HQ COMMENTS: Replace HVR. The HVR in this unit affects the horizontaloscillator via R540, D505 and R549. This is also a common problem withmodel PVM-19



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads