SonyWMD6CNO MOTOR MOVEMENT 0.5 Volts across BE junction of Q-601 collector was at 0V.0V was measured from IC-601, pins 12 and 14, to ground - resistance frompin 12 to ground was 0 Ohms.
SonyFD45APART NUMBER FOR SPEAKER Part number for speaker in service manual is missing. -HQ COMMENTS: There is no separate part number for the speaker. Itis part of the front cabinet. When you order the new cabinet make sure toorder the correct color cabinet.White X-3336-107-1Yellow
SonyPVM2530HORIZONTAL LINE ON CENTER SCREEN Screen appears completely black with the exception of ahorizontal line across the center of the screen.
SonyTCWR9ESQUICK AUTO REVERSE Unit will not Quick Auto Reverse on both decks as advertisedin the attached brochure. According to service manual, only B deck hasthe circuit for Quick Auto Reverse as shown on the schematic attached. -HQ COMMENTS: Thanks for the info. You are right, a
SonyCCDV9COLOR DISTORTED AND FLASHING Color distorted in Play, ok in Pause. Sometimes colordistorted in Pause, ok in Play.
SonyCCDV11DEW SENSOR ON DEW sensor on.
SonyCCDF40POOR PLAYBACK Playback picture on TV monitor displayed bad heads, but RFenvelope looked good. Traced signal to soft limiter circuit where RFentered but left distorted Q-376, 378 and 379 had no 5V supply.
SonyMDP210NO VIDEO OR RF Unit read disc and had audio but no video or RF. Found videoat pin 13 of IC-103 but not at pin 13 of IC-602, nor at Q-610.
SonyWMA39WRONG PART NUMBER LISTED IN MANUAL Part number for reference number 904 is listed as1-623-643-11. This is wrong (page 12 of manual).
SonySPPS10TEST CONNECTOR FOR ALIGNMENT OF RF SECTION. How do you align RF section?
SonySPP60TEST CONNECTOR FOR ALIGNMENT OF RF SECTION How do you align RF section?
SonySPP50TEST CONNECTOR FOR ALIGNING RF SECTION How do you align RF section?
SonySPP90AFTER GRABBING THE LINE, UNIT SHUTS DOWN AFTER A FEW SECONDS When Talk button on Handset is pressed, Base unit and Handsetgo on-line normally. After about 30 seconds, Base unit drops theline and Handset goes back to Standby mode. If Talk button is pressedagain, same situation occurs.
SonySPP80AFTER GRABBING THE LINE, UNIT SHUTS DOWN AFTER A FEW SECONDS When Talk button on Handset is pressed, Base unit and Handsetgo on-line normally. After about 30 secs., Base unit drops the line andHandset goes back to Standby mode. If Talk button is pressed again, samesituation occurs. Also applies to S/N 226939, 2
SonyTCDD10DISTORTED AUDIO DURING PLAYBACK Plays normal for 30 seconds or so then bursts of static noise,then goes to all garbled static noise, then finally to no sound. Some-times after this, it will stop playing and unthread. REC loop-through isfine. I have replaced IC-301, IC-311 and IC-529



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.