SonyKV36XBR200
AA-2H
GEOMETRY KV36XBR200. Serial 9016768. "" Unit has pincushion error o the top of screen. Area around the extreme edges of the fields do not have straight lines. Horizontal lines have a shoulder roll off. Tech ordered Yoke specific to bulletin # 387 , but received the complete CRT. I held off replacing the CRT due to three of these have been changed so far with no changes in the symptom ""Bulletin 387 did not mention a THL plate which needed to be adjusted was in the old deflection yoke. After following the new bulletin 387R1 we were able converge the set. Also the new tube needed 3 magnetic on the bell of the tube to correct a purity error and converge the lower right hand corner. Muller
SonyKV36XBR200
AA-2H
GEOMETRY KV36XBR200 Picture is tilted. There is insufficient range in the tilt adjustment Use part number out of bulletin 379 for the pix tilt correction coil. Muller
SonyKV36XBR20 0
AA-2H
FOCUS KV36XBR200 serial 9023068Out of focus on the extreme horizontal edges of the screen. The last 3 inches have a noticeable focus error CRT...Attempting to move the focus control does not cause the area on the outside of the CRT to change focus. Unit may have Bad CRT. Muller
SonyKV36XBR200
AA-2H
arcingKV36XBR200 Unit has an intermittent arc over that will shut down the television. The best way to tell if the arcing is related to the HV lead which may be breaking down is to use a high voltage probe. Connect the ground to the CRT ground and run the tip of the high voltage probe over all high voltage connections & wires. If an arc is drawn to the probe tip this would mean that a break down in the insulation has occurred. This test revealed a break down in the High voltage connection at the High Voltage anode button. The silicone sealant did not seal between the HV button and HV cup. Cleaning the area around the anode button, replacing the anode cap and resealing the connection with high voltage silicone sealant. Muller
SonyKV32FV1
AA2H
tuning KV32FV1 serial 9002390 Main tuner will not tune any channels but the PIP tuner is fine. Tuner was changed without any change in the symptom. Set just displays snow on all channel from the main tuner and the OSD for main channel display is normal. I had tech check the B+ on the tuner that are stamped on the board. The 9, 30 & 5 volts are normal. The SCL line is only 2 volts and the SDA line is 4.6. The SCL line is the trouble. Tech did not have an oscilloscope but since the SCL line for this tuner is the same for the PIP tuner we concluded the CPU was not at fault. There appeared to be an open between the SCL of the main tuner and CN1101(6). Since the traces on the CBA are so thin the and no cracks in the board material could be seen the decision was to install a small jumper wire between these two points. This corrected the Muller
SonyKV32FV1
AA2H
remote Unit does not operate with remote control. Front panel controls are operating OK. Unit has ""0"" volts on the output of the IR receiver IC2001(1) This should be 5 volts as long as it is not receiving data. Customer has an RCA DVD player connected using the S-video input and the S-Link too. Sony's S-Link is not compatible with RCA's G-Link input used to control operational functions. Disconnect the S-link / G-link connections and restored operations. ""Muller
SonyKV32FV1
AA2H
remote KV32FV1 Unit does not operate with remote control. Front panel controls are operating OK Unit has ""0"" volts on the output of the IR receiver IC2001(1) This should be 5 volts as long as it is not receiving data. Customer has an RCA DVD player connected using the S-video input and the S-Link too. Sony's S-Link is not compatible with RCA's G-Link input used to control operational functions. Disconnect the S-link / G-link connections and restored operations ""Muller
SonyKV32XBR200
AA2H
NO HIGH VOLTAGE KV32XBR200 9015636 Unit will click on then it will turn off again. Does not get high voltage. Unit has b+ to horizontal output but no horizontal drive. If the Horizontal output is removed the set will produce the necessary drive signals. Collector of H. driver Q501(C) measures 85 with Horizontal output removed. Unit appears to have a shorted Flyback or a problem in the horizontal output section that caused the OCP circuit to attack. Product had a defective Flyback transformer. Muller
SonyKV36FV1
AA2H
GEOMETRY KV36FV1 serial . Unit has shoulder roll off on the screen. Gave tech bulletin #387 for the yoke upgrade Muller
SonyKV32XBR200
AA2H
GEOMETRY KV32XBR200 Unit has just had the new CRT with the attached yoke replaced today to correct the Shoulder Roll off symptom as described in Bulletin 387R2. However the new tube and yoke did not solve the vertical pincushion symptom See bulletin #387R1 Muller
SonyKV32XBR200
AA2H
GEOMETRY KV32XBR200 Unit has just had the new CRT with the attached yoke replaced today to correct the Shoulder Roll off symptom as described in Bulletin 387. However the new tube and yoke did not get installed. Instead we are going to contact Sony Bulletin 387 did not mention a THL plate which needed to be adjusted was in the old deflection yoke. After following the new bulletin 387R1 we were able converge the set. Also the new tube needed 3 magnetic on the bell of the tube to correct a purity error and converge the lower right hand corner. Muller
SonyKV32XBR200
AA2H
GEOMETRY KV32XBR200 serial # 9018039 .Unit has ""Shoulder Roll Off"" symptom as described in Bulletin 387. Tech will be ordering new yoke and needs the part number ""We have changed several yokes so far as of 4-2-99 WITH LIMITED SUCCESS. Performing a complete setup of purity, convergence and geometry setting corrects most of the geometry errors. However this set will not be perfect. Muller
SonyKV32XBR200
AA2H
GEOMETRY KV32XBR200 serial # 9008075 .Unit has just had the new CRT with the attached yoke replaced today to correct the Shoulder Roll off symptom as described in Bulletin 387. However the new tube and yoke did not solve the vertical pincushion symptom Bulletin 387 did not mention a plate which was in the old deflection yoke. The missing THL plate needed to be removed from the old yoke and placed in the same slot in the new yoke . After following the new bulletin 387R1 we were able converge the set. Muller
SonyKV32FV1
AA2H
focus KV32FV1 Unit has poor focus on the left and right side of screen but OK in the center. If the focus control is varied through its range the sides will become in focus with the center out of focus. Since this set has the super flat CRT. It incorporates a dynamic focus circuit. In other words the focus voltage varies as the beam travels from left to right. Measuring the Horizontal parabolic wave form up to the input of the primary of the DF transformer, we found the signal to be normal. We were unable to measure the voltages further because they were potentially focus voltage potential. The horizontal parabolic wave form enters the Flyback at the secondary of the DF transformer. Unit had defective flyback transformer. Muller
SonyKV35XBR48
AA-2
WRONG COLOR KV35XBR48 serial 01901543. Customer using this television on a DVD player and has it connected through the ""YUV"" inputs. The gray scale is favoring the green color temperature even if no color is present on the screen. Playing back the same signal in the Composite input or the S-video input the color temperature is normal with normal black and white tracking. It is thought that a separate black and white tracking or RGB drive adjustment in the YUV mode will solve this trouble. ""According to Sony there isn't any drive adjustments in the YUV mode. This symptom shows up on another Sony television of the same model. Sony claims this is a normal function and there are no plans to address this phenomena. There is nothing wrong with the Television It is operating as designed. Muller


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.