Dicas Reparação TOSHIBA




Modelo - Chassis


Pesquisa: TOSHIBA Enviar Dica Resolvida
Resultados 4731
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Toshiba215T8B
Stuck in standby.CHECK VOLTS AT PIN 7 ( 5V RESET ) OF MICRO QA01 if low check Q805 if ok ICA01 u/s PTNo 23318387 - M34300N583SP
Toshiba215T8B
NO TEXT , JUST PAGE NUMBER ( WHICH CAN BE ALTERED )CF14 0.01mfd
Toshiba215T8B
LOW BRILL/CONTRAST , POOR FOCUS , LOOKS LIKE LOW EMMCHECK R920 ( 3ohm ) CRT HEATER SUPPLY
Toshiba215T8B
INT. FIELD-LINE COLLAPSEDRY JOINT SCAN COIL CONNECTOR P570
Toshiba215T8B
Field foldover/cramping at topIC340 TDA2579
Toshiba215R8B
No pic Int CRT htrs - dry joints at P502 (under plastic loptx cover)
Toshiba215R8B
Field linC317 4µ7 50v
Toshiba2151TB C4ER
Trips off aft few secs - HT highHT rose to 150v (115v) C817 22u 100v o/c
Toshiba2151TB
stuck in stbyQA10 2SC1815Y or 2SC1740 leaky (reset for Micro ICA01 pin 43)
Toshiba2151TB
goes dead ofter 5-10 minQ831 2SC1815 leaky
Toshiba2151DB
No line or field syncIC501 TDA8361
Toshiba214T7B
DEAD STBY LIGHT GOES OUT WHEN REMOTE PRESSEDC815 .039uF
Toshiba214R7B
Pulses on hi brillD242 1N4148 in beam curr lim s/c
Toshiba214R7B
No soundTDA1015 (IC621) audio output amp and feed resistor R830 0.56R connected to pin 4 of the chopper TX.
Toshiba214R7B
Int reverts to st/byDry joints pri joints st/by tfmr


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.