Dicas Reparação HITACHI




Modelo - Chassis


Pesquisa: HITACHI Enviar Dica Resolvida
Resultados 1003
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
HitachiC2556TN
Int goes dead only to reapear several secs laterDry joints pot R950 - tight up against plastic cradle
HitachiC2556TN
Int deadcheck dry joints IC951
HitachiC2556TN
INT DEADDry joints set HT pot
HitachiC2556TN
DeadR950 68k ½w hi res (near ht pot)
HitachiC2556/2586
HT setting152v
HitachiC2548TN
Jumping picFOP chip responsible
HitachiC2546TN
Tripping Check R950 68k, R951 12k, R952 82k 1/2w & check for dry joints
HitachiC2546TN
Stuck in st/by prot cct in operation12v supply low - ZD952 11v zener leaky
HitachiC2546TN
St/by onlyDrys on all regulators check frame ic replace 68k feed to ht pot and check the 12k next to it replace ht pot set ht to 152 volts and dry on R791
HitachiC2546TN
St/by LED lit - HT to LOP stage but no line driveDry joints Q950 reg (under plastic support)
HitachiC2546TN
Reverts to st/by aft a sec with "growling"Scan coils duff
HitachiC2546TN
Red cast to pic when col control increasedIC501 TDA4665 dig delay line chip
HitachiC2546TN
No soundMemory chip replaced
HitachiC2546TN
INTETMITTANTLY CUTS OUTRESOLDER IC951
HitachiC2546TN
Int reverts to st/byDry joint on R956 to left of reg & check reg joints


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.