Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Hitachi | C2514T | NO PICTURE OR SOUND ALL CONTROLS SET TO "0" AND SE | R086 D/J | ||
Hitachi | C2514T | Int trips into st/by esp on vcr chan | R951 & R953, Both 82k 1w - going high | ||
Hitachi | C2514T | Dead - ZD952 P6KE180A zener s/c | R951 82k has gone high in value | ||
Hitachi | C2514T | Blank raster - all controls at zero | R068 had never been soldered | ||
Hitachi | C2509T G7PS | Field - bottom cramp | C606 680mfd 16v scan coupling cap | ||
Hitachi | C2509T | Dead | Replace ZD903, Q903, Q781, C906, 908, 913, 908, 905, 720, RV901. R901, 910, 760, 761, 762, 768. ZD903 split in 2 | ||
Hitachi | C2508T | Unstable pic until heated | C922 faulty | ||
Hitachi | C2508T | Long time to come on | Mains smoothing cap 150µ 400v virtually o/c | ||
Hitachi | C2508 | Tuner drift on upper bands | ZD101 33v stab | ||
Hitachi | C2508 | Int dead & makes screeching sound when it does | Mains smoothing cap 150µ 400v low cap | ||
Hitachi | C24Wxx/28Wxx | HT setting | 152v | ||
Hitachi | C24W511TN | Int reverts to st/by | R959 15k was making int contact with the board (production fault) | ||
Hitachi | C24W410SN | EHT surge at sw on then reverts to st/by | Dry joints on IC951 and IC952 (Voltage regulators) | ||
Hitachi | C24W410SN | EHT crackling with HT too high | ZD950 O/C 10 volt special zener T536207 also replace C601 and C611 220mfd | ||
Hitachi | C24W410 | Int cuts out - esp when tapped | Dry joints VR950 under plastic frame |