PanasonicAlpha 4
Blank raster - sound ok - same on scart; on Txtshows "P100" at the top left and "*** TXT ***" flashing at the bottom centre of the screen.Replace IC3002 (M52472P) on the "H" panel.
PanasonicAlpha 3 TX28A2X
E-W bowingR751 33R o/c
PanasonicAlpha 3 TX28A2
Txt lines at top of picC454 ( 4.7 uF; C455 ( 100 uF ) and frame output I.C. AN5521
PanasonicAlpha 3 TX25W2
Txt fault - header unstable & unsync in mix modeC3511 220pF on board H (connected to pin 24 timing of SAA5231 IC3501)
PanasonicAlpha 3 Alpha 3
No sound - dark blank raster.C1251 ( 10nf ) leaky , main microcontroller & memory chips.
PanasonicAlpha 3
Txt poor with missing lines & corruptC3507 100pF leaky to pin 9 IC3501
PanasonicAlpha 3
Txt - no pages but header present or jumping TxtC3511 220pF ceramic cap on Txt panel leaky
PanasonicAlpha 3
The Panasonic Alpha 3 ChassisSee TV Mag Mar-Jun 1994
PanasonicAlpha 3
Stuck in standby.LOPTX
PanasonicAlpha 3
St/by onlyQ825 opto driver hard on. Removing R843 which links base of tr to micro power on/off pin produced a blank raster. Micro reset line stuck at 2v instead of 5v - C1251 10nF was leaky
PanasonicAlpha 3
Red & Green 'gliches' across screen intOK in Txt mode - C649 120pF faulty - pin 3 IC302 transient improvement chip
PanasonicAlpha 3
R822 4R7 10W SURGE LIMITER BLOWN , WHEN REPLACED RREPLACE C501 0.1uF
PanasonicAlpha 3
Poor focus - adj focus varies brillinternal leak in CRT between A1 and focus electrodes
PanasonicAlpha 3
No tuning memoryChip select signal from pin 53 of micro to memory chip missing - L1209 o/c
PanasonicAlpha 3
No g in txtD3309 o/c - D3308 or D3310 could cause same problem with other cols


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.