Dicas Reparação Panasonic





Pesquisa: panasonic

Resultados 2648

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PanasonicAlpha 1
Q551 KEEPS BLOWINGCHECK DRY-JOINTS ON LINE OUTPUT TRANSFORMER
PanasonicAlpha 1
Plain blank raster & no sound , no OSD sync - Ok via rear sockets.Replace IC101 ( TDA4505M ) in side can middle of chassis.
PanasonicAlpha 1
Pic goes in from RH side with black line across centreDry joints field o/p chip
PanasonicAlpha 1
Pic brightens & drops with dist field scan when heatedScan coils faulty - reqs replacement of crt as they are bonded
PanasonicAlpha 1
off - safety res R851 2R2 o/c when replaced loud buzzwhen base of line driver tr lifted buzzing stops. No line drive replaced TDA4505M-N3 jungle chip (must be correct suffix)
PanasonicAlpha 1
No sound/pic off air or via scartIC2601 M51320P AV sw chip - to check, remove chip & jumper I/P & O/P pins
PanasonicAlpha 1
No sound or picture - squealing.Line drive transformer.
PanasonicAlpha 1
No pic/sound - chan ind lit, psu whiningC808 hi esr, R567 pt no TSF19102 (fuse) - used 1.4A Wickman
PanasonicAlpha 1
No colReplace sub carrier trimmer and adj; check PAL delay line by subst
PanasonicAlpha 1
LOPTr Q551 int blowsCheck dry joints line dr trfmr & R567 1A fusible resistor
PanasonicAlpha 1
Lines with whistleC808 10µ 63v
PanasonicAlpha 1
Lack of height - lin okFit 3R3 resistor across R461 to increase height
PanasonicAlpha 1
Lack of col at top of pic whilst playing pre-recsChange C604 from 0µ047 to 0µ33
PanasonicAlpha 1
Int flicks off tune with momentary bright blue rasterChopper chip IC801
PanasonicAlpha 1
High HT (128 instead of 119v)C808 10µ 50v hi esr



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads