SanyoCE28WN4 EB6A
Excess width & no E/W after LOPTx replacementD469, C463 (10nF 50V) and Q462 (used a 2SD1207),C465 (33nF 50V) and D463 both s/c
SanyoCE28WN4
St/by only shortly after fitting B10H04NIC mod kitIC802 the PROM which is part of the kit was faulty
SanyoCE28WN4
EEPROM ProblemsThere is a mod for this set, part No B10H04NIC the micro doesn't get enough info on shutdown and reverts to default values, hence very big pic! Service mode is accessed by pressing the green button on the remote followed by prog down on the set.
SanyoCE28FWN2
Dead - 4A internal fuse o/cReplacement brought set to life - no other fault found
SanyoCE25DN5 -EB6a Chassis
To enter option modehold the F/OK button on the r/c and press the P -(down) on the tv. Highlight the desired option using the P +/_ button. Vol +/- to change option selected. To exit press the recall button.
SanyoCE25BN2 EB4-A25
No pic - HT only 125v (150v) - sound presentDiss any of secondary supplies corrects HT. When Q611 and Q612 and D617 in psu pri removed for testing & replaced cures fault!
SanyoCE21DN3B
Dead with led flashingR624 120k o/c also check R620 120k
SanyoCBT2146
Txt corruptIC1031 SAA5240A
SanyoCBT2146
Poor syncIC1011 SAA5230
SanyoCBT2146
Pic fades aft sw ondry joints R479
SanyoCBT2146
Lack of width & field foldover when heatedC310 0.047µ 50v
SanyoCBT2146
Int red picDry joints A602 on crt pcb
SanyoCBT2146
Corrugated vertsEHT lead conns
SanyoCBT2146
Bright raster with fb linesR478 10R o/c
SanyoCBR2148
Replacement of TDA4505M - NLAUse TDA4505E & change R136/121 to 470k & adj AFC as nec


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.