SintomaCausaSoluçãoPor:
SanyoC21EF25NB EB2ATrips several times at sw on - intBlack jumper wire in front of chopper tfmr dry joint
SanyoC21EF25NBTrippingDry joint J136 link
SanyoC1461A EC1V7Dead - LED blinks at start upR858 560k o/c
SanyoA5-A21int pic break updry joints 12v reg IC551 & IC552
SanyoA5 chassisReverts to st/by aft few secs from sw onPin 19 of micro low - R748 100k pull up res faulty
SanyoA5 CBP2180A Field collapseL451 connection faulty (hidden under a blob of glue)
SanyoA5 CBP2180int. frame collapsereplace L451 33uH (int. o/c, delivers 24V supply from LOPTx pin 6)
SanyoA5 CBP2180int. dead resolder Q432
SanyoA3A20 SEP6022White raster with linesC562 22µ 250v
SanyoA3A CEP1495Negative picIC101 LA7680
SanyoA3 CBP3024deadLOPTr Q432 2SD1649 s/c, R555 47k o/c
SanyoA1-A14St/by only - light off when R/C operated130v HT & 24v supply present - no 12v pin 8 IC201. C422 0µ0033 leaky
SanyoA1-14Rolling non-lin picR548 hi res (varies with model - 180k typical)
Sanyo83P-D20Colour - varing.C283.
Sanyo83Pswitches chans when heated & hum barMains smoother 130µ 400v u/s



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.