SharpS3B
Q603 lop tr 2SD1554 s/cevidence of overheating - check drive wfm - if low change D601, 603 & 607 1N4004
SharpS3B
no pic - rushing noise from spkr9.5v supply missing - R745 0R33 o/c
SharpS3B
low contrast with flashesBF421 tr on crt base (auto grey scale)
SharpS3B
flickering picBY299 D713 high fwd res
SharpEURO-DS
off - no st/byC707 22µ 50v
SharpEURO-DS
field collapseIC1402 NVM3060 can be corrupted - check location 7A should be 00
SharpEuro DS1
off with faint whistlinglopt
SharpEuro DS1
blue screen onlysupply to IC250 pin 7 missing - C257 33µ 16v s/c & D250 2v1 zener o/c
SharpEuro DS
dead low, varying ht 10-50vht pot int
SharpDW100 66FW53H
Dead - usually IC705 opto is to blame - Pt. No. RH-FX0106BMZZchanged to RH-FX0110BMZZ - When the opto fails it usually takes out the line output transistor(BUH515) and the feed resistor to the line o/p stage 1R2W resistor. You need to add a 145v avalanches diode to the circuit on the print side directly beneath C720(H.T. reservoir cap) which also will need to be replaced.
SharpDV6632H
TrippingDry joints scan coil plug & leaky LOPTr BU508AF
SharpDV6632H
Shuts down completely aft Red then green LED briefly litField o/p chip TDA8170 & R645 1R 1w - check 3x100µ caps behind fop chip
SharpDV6632H
Ragged verts & E/W distC623 4µ7 63v in E/W cct by Q603
SharpDV6632H
FB lines at top (R,G,B) & shaking pic with pullingC506 100µ 65v, C623 4µ7 100v
SharpDV6632H
Dead - chopper tr 2SD1546 s/cCheck dry joints in psu esp on Q603 & R710 100k 2w hi res & IC700 MC446022P2 shorted


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.