SintomaCausaSoluçãoPor:
SharpDV5161H
WORKS FOR 1min THEN SHUTS OFF. ALL SECONDARY SUPPLC711 1n 2kv
SharpDV5161H
White raster with fb lines & tripsR612 22R fusible o/c
SharpDV5161H
St/by onlyNo 12v supply; D602 1N4936 o/c
SharpDV5161H
No sound/pic - screen lit with lines with half screen darkerFOP chip - gets hot!
SharpDV5161H
HEIGHT VARIES WITH PIC CONTENT FIT MODS , ADD 270KADD 110K 1/8W BETWEEN CATHODE OF D801 AND GROUND , - CHANGE C832 TO 100nf , CHANGE NVM TO NEW SOFTWARE VERSION ( Sharp CH-IX1
SharpDV5161H
Electronic Screwdriver Wire link pins 3 & 6 of plug TB on txt panel. Press "mode" on hset. "Serv" appears on screen. Remove link & use up/down buttons to view menu settings. Press "Mode" button again to exit settings
SharpDV5161H
Dead green LED lights briefly flashing redDry joints C610 near LOPTx
SharpDV5161H
Dead - loptr s/c - R604 flamingR649 15R 1W across Q1010 coll/emitter hi res & replace R604 3k3 1/3w safety res
SharpDV5161H
Blows lop tr aft few minsTuning caps C607, 608, 609 & 610
SharpDV5151H
LOSES COL AFTER CHAN CHANGE , SLOW TO LOCKADD 8.2 MEG BETWEEN PINS 25 AND 39 OF IC801 Sharp VRD-RA2BE825J
SharpDV5150H
Reverts to st/by aft 2 secsNo 24v supply to FOP chip as R612 3R3 safety res o/c - Sharp mod - fit 2R2 safety res & link J13 replaced by 1R2 ½w res
SharpDV5150H
Int goes off with crackleDry joints C603 6n8 1.5kv
SharpDV5150G
Dead led flashes redCheck R612, 621 & C714 1000µ? 16v
SharpDV5150G
DeadR728 3k3 safety res overheating, chopper tfmr shorted turns (draws 500mA off load -should be only 120mA)
SharpDV5150 S3B
Field top stretchedC712 100µ 35v in 24v supply


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.