SharpDV51083H D3000
Dead. When the collector of the 2SD1546 line outpuThe line output transformer was faulty. Fit a replacement and power the set up slowly via a variac. If at about 100V input th
SharpDV51083H D3000
Dead - HT presentC715 1000mfd 16v in 5VM supply
SharpDV51083H
Tripping & various faultsFault on digital sub panel (uses the ITT Digit 2000 chipset) & is very unreliable - as each chip costs £20+ & entire panel replacement is advised by Sharp (£200) - repair is usually uneconomic
SharpDV51083 D3000
Trips after LOPTx replacementFOP chip TDA8175 s/c & supply res 1R o/c
SharpDV51083 D3000
Tripping continously - int originallyC715 2200 16v LT res cap low cap
SharpDV51083 D3000
Dead - HT ok when LOP dis'dLOPTx faulty
SharpDV51083
Weak R when heatedSet up grey scale via hset
SharpDV51083
DeadC710 1000µ 25v, C734 100µ 25v hi esr
SharpDV5107H DV5132 D
NO SYNC OR NO COL , NVM DATA COUPTADD 8.2v ZENER BETWEEN PINS 5 AND 8 OF IC1003 CATHODE - PIN 8 Sharp RH-EX0413BMZZ
SharpDV5107H Deco 4
Dead with 2A mains fuse blownS/C across chopper Tr was chopper trfmr s/c pins 2, & 6 but when replaced, fuse blew again due to chopper Tr MJF18006 going s/c - also worth replacing TEA1039 chopper chip IC700
SharpDV5107H
Reverts to st/by intC721/ C719 10µ 50v; C722 100µ 16v; C723 4µ7 50v cured it
SharpDV5107H
R612 FAILS FOR NO REASONCHANGE R633 TO 2.2ohm Sharp -XZ0204BMZZ ( R633 SAME AS R612 )
SharpDV5107H
No start up - LEDs flashing red/greenHT high at 156v - LOPTfrmr & check 0R33 in psu & caps
SharpDV5107H
Dead - LED flashes red/greenLOPTx
SharpDV5107H
Dead - keeps blowing LOP trsLine drive int - replaced tbase/RGB daughter board - used board from DV5105 - physically larger but electrically works ok


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.