SharpDeco5
Line collapse then deaddry joints C604, replace R610 68R 1/2w fusible & Q602 loptr
SharpDECO4 DV5105H
Trips at sw on then comes back on but trips again on chan changeR716 0R22 in psu gone slightly hi
SharpDeco4
stuck in st/by; 5v supply faultR751 0R33 risen to 1R
SharpDeco4
MJF18004C chopper tr & TEA1039 chopper chip s/c between pins 9 & chassisR706 & 710 3R3 safety res o/c - after replacements fitted blew again. T700 chopper tfmr internal short
SharpDECO 5
Screwdriver settingsBriefly connect pins 2 & 6 of connector CN1 on middle pcb ( Pin 1 farthest away) Using chan up/down & Vol up/down buttons to locate & adj options, save each setting with on/off button. Exit serv mode by briefly connecting pin 2 & 6 CN1 again.
SharpDECO 5
Line coll then deadR610 68R 1/2W FUSIBLE O/C;Q602 BU508AF LOPTr S/C; DRY JOINTS C604 was the cause
SharpDeco 5
Int won't come out of st/by - led flashes R&G5v line ok - others pulse, R793 0R33 1w risen to 0R6 - by chopper tfmr
SharpDeco 5
Dead - red/green flashing ledR751 0R33 safety res had risen to 0R59
SharpDeco 4 DV5105/DV5107
won't come on from stby when remote is used, green and red LEDs flash. But it would come on Ok when mains switch is used.R751 0.33R o/c
SharpDeco 4 DV5105/DV5107
dead, no PSU output, R705 burntIC700 TEA1039 pin 9 leaky to pin 7, R705 3k3 0.5W fusible (RRXZ0242BMZZ), also check D705 1N4148 and Q701 BC635
SharpDA100W 76EF20H
stuck in stbyLOPTr Q601 BUH1015HI leaky
SharpDA100W 76EF20H
no sound, no pic. HT Ok but no line driveDJ on plug P703
SharpDA100 66FW53H
narrow pic with E-W errorreplace IC801 (RHIX1688BMZZ)
SharpDA100 66FW53H
green gun reduced to give a magenta piccorrupted EEPROM IC1003 (RHIX1603BMZZ)
SharpDA100 66FW53H
dead, stby LED is onQ5407 2SA1837 and Q5408 2SC4793 s/c on CRT base


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.