Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Sharp | CA10 66DS05H | INTERMITTENT STANDBY AT HIGH VOLUME | CHANGE VALUE OF C335/C336 TO 022MFD | ||
Sharp | CA10 66DS05H | Field lin problems | Check F601/2 o/c | ||
Sharp | CA10 66DS03H | STUCK ON 1 CHANNEL, NO REMOTE OR FRONT FUNCTIONS | REPLACE R705 68K | ||
Sharp | CA10 66DS03H | St/by only | LOPTr s/c due to almost invisible dry joints on scan coil conn | ||
Sharp | CA10 66DS03H | NO REMOTE OR FRONT FUNCTIONS | CHECK R704/705 FOR O/C OR HIGH VALUE SHOULD BE 68K | ||
Sharp | CA10 66DS03H | No control via front or remote | R705 68k st/by 5v feed | ||
Sharp | CA10 66DS03H | Field - bottom ok top squashed with lines | F601 N27 2.5A fuse | ||
Sharp | CA10 66DS03H | Dead with whine from psu | Dry joints C613 680n - replace cap & resistor across it | ||
Sharp | CA10 66DS03H | Dead - LOPTr Q602 BUH515 s/c | C604 | ||
Sharp | CA10 66DS03H | Dead | Dry joint & o/c C613 680n & res across it o/c- to rt of Loptx | ||
Sharp | CA10 66DS03H | BOTTOM HALF OF PICTURE OK TOP IS LINES WITH E/W DIST | REPLACE F601 NEAR LOPTX | ||
Sharp | CA10 59DS05H | PSU cuts out as pic appears | Check R721 100k, R704 68k, R705 68k, R703 100k | ||
Sharp | CA10 59DS05H | No sound & only bottom half of raster | R530 1R fusible o/c; sm cap 0.1µ (estimate) connected between D516 & chassis leaky | ||
Sharp | CA10 59DS05H | No pic - L604 overheating | C613 68nF 250v, C619 2µ2 160v, & R613 2k2 2w. Also check Q602 BUH515 | ||
Sharp | CA10 59DS05H | Dead | Dry joints C613, lop tr s/c & R613 2k2 hi res |