Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Sharp | CA10 59DS03H | St/by only | 2 x 560k start up res o/c (hidden by chopper tr heatsink) | ||
Sharp | CA10 59DS03H | PARTIAL FRAME COLLAPSE | REPLACE F0601 F0602 AT REAR OF PCB | ||
Sharp | CA10 59DS03H | NO REMOTE OR KEYPAD FUNCTIONS | REPLACE R705 68K | ||
Sharp | CA10 59DS03H | FRAME COLLAPSE | REPLACE F602 | ||
Sharp | CA10 59DS03H | Field scan at top stretched | Scan coils faulty - do not run for long - risk of crt neck damage | ||
Sharp | CA10 59DS03H | Field - no pic at top ½ of raster | Field stage is supplied with + & -ve supplies fused by F601/2. Check these & Q501/2. Q501 faulty & replaced with a IRFI9020 (uprated device) | ||
Sharp | CA10 59DS03H | Dead with mains fuse o/c | Q701 chopper FET s/c RH-TX0166BM22, D712 zener RH-EX0419BM22, BUH515 LOPTr - if stuck in st/by aft replacement Q702 BC338 in psu s/c | ||
Sharp | CA10 59DS03H | Dead apart from power light | 2 x 560k start up res hidden under chopper heatsink | ||
Sharp | CA10 59DS03H | Dead apart from neon glowing | R703/705 68k hi res | ||
Sharp | CA10 59/66DS03H | set won't start (no line drive) | D602 s/c in -13V supply (RHDX0504BMZZ) | ||
Sharp | CA10 59/66DS03H | partial frame collapse and foldover | replace fuses F0601, F0602 rear of PCB, upgrade to 2.5A. If fuses Ok, check R617 22R | ||
Sharp | CA10 59/66DS03H | no sound on speakers, Ok on headphones | SMD C2310 33nF leaky (45V line down to about 30V) | ||
Sharp | CA10 59/66DS03H | no remote or local buttons function | R705 68k o/c (no supply to IC702) | ||
Sharp | CA10 59/66DS03H | no remote or front control functions | R704, R705 68k 1W in 5V supply to Micro are high or o/c | ||
Sharp | CA10 59/66DS03H | frame collapse | fuse F602 o/c (QFSJ2521CEZZ) |