Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sharp | C2072 | No sound - o/p stages working | R319 270R o/c | ||
Sharp | C2072 | Lack of height | Set running perm off start up supply - R237 15k o/c or dry joint Q209 | ||
Sharp | C2051 | Tuning drift | Q104 2SC458A on sensor panel | ||
Sharp | C2002 | Standby - no switch on some times from s/by. | R717 ( 390k ) , C720 , R712 , last IC701. | ||
Sharp | C2002 | Dead. | STR4090. | ||
Sharp | C1891 | No colour. | I801 ( RH-1X0109 ) , Q407. | ||
Sharp | C1891 | Int brightness variations | Hi value resistors in A1 supply | ||
Sharp | C1891 | Brightness variation. | Resistors in series with first anode control arcing. | ||
Sharp | C1871 | Frame collapse. | R525. | ||
Sharp | C1871 | Field partial collapse | R525 | ||
Sharp | C14ET1EK | Bright blank raster with no sound | Check spker plug in CN201 NOT CN602 | ||
Sharp | C1495 | Field collapse | R511 15k & R512 1k2 o/c | ||
Sharp | C1495 | FIELD COLLAPSE | R511 15k R512 1k2 | ||
Sharp | C1451SC | Foldedover picture,reduced height and visible white line in te centre of screen. | Change C508 2,2uF/35V tantalum cap. Seemed to be O.K with a VOM. | ||
Sharp | C1451SC | Foldedover picture,reduced height and visible white line in te centre of screen. | Change C508 2,2uF/35V tantalum cap. Seemed to be O.K with a VOM. |