Sharp5BSA 51AT15H
Corrupted service mode settings after replacement of Q601/2No stopping when tuning, height and vert posn out - set AFC optione byte to '9F'
Sharp5BSA 51AT15H
appears dead, LED is greenQ704 BC338 o/s
Sharp5BSA 51AT15
Dead symptoms with psu runningNo line drive base Q603, no 5v supply pin 8 EEPROM IC1002 as 5v reg tr Q704 BC338-40 o/c emitter
Sharp5BSA 37AM23
No line drive - some soundQ 605 (s.m. pnp transistor) was O/C
Sharp5BS-A
int snowy - when tappedSF201 SAWF
Sharp5BS-A
Field scan reduced with cramping top/bottomCheck- C712 220µ, C713 1000µ, Q502 BD825, Q504 BD828, Q509 BC635, Q510 BC338, D501 1N4148
Sharp5BSA
Various inc field cramp, r/c non funct & int lop tr failureC713 1000µ 16v in -10v line
Sharp5BSA
tuner drift - exasapated by pcb flexC1013 100n sm cap cracked & leaky
Sharp5BSA
To enter service modePress chan up & down buttons together whilst sw on tv
Sharp5BSA
slightly off tunereprog afc - loc OD - set data to 9F - how to access prog mode??
Sharp5BSA
No TxtQ806 sm 2SC2412 - feeds CVBS sig to pin 30 micro IC1001
Sharp5BSA
No sound/pic & all o/p volts a third down Q509/510 in fop s/c
Sharp5BSA
No sigs - searches but won't storeAFT switched off in service mode
Sharp5BSA
Int dead then perm deaddry joints, R611 3k3 ½w was 2k5, no line drive - no 5v to IC801pin 35. Q708 BC338-40 reg o/c
Sharp5BSA
Incorrect line freqcheck supply to IC801 MC44007 - if low check caps in psu - C713 1000µ 16v, C712 220µ 16v, C714 470µ 10v, C716 100µ 16v, C719 470µ 35v & C604 / C622 220µ 10v in line dr


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.