SonyCCDV8AFU
DISTORTED SOUND RECORD OR P.B. Playback of prerecorded tape or tape recorded on unit was gar-bled. Checked pin 13 of IC401 and VCO frequency was approx. 1MHZ. RV402would adjust freq. from .9MHZ to 1.29MHZ. Found bad connection on R434.Pin 46, IC401, remained at 2.13VDC all the time
SonyKV25VXR
TIME ACTIVATED OPERATION MALFUNCTION When the unit goes into RECORD PAUSE MODE, unit shuts itselfoff and memory gets wiped out. Found D602/5.6V zener) on (D) board de-fective causing no vertical pulse to PLL Contr. p4/IC103 and negativepulse at p58/IC2004 (Res. Out) at the REC. PAUSE insta
SonyPSLX355
SCHEMATIC ERROR On pages 6 and 7 power and ground are indicated reverse towhat they should be on power input connector. HQ COMMENTS: Thank you for your information. We informed Tokyo of thisproblem, however, the service manual was correct.
SonyCDP255
IMPROPER CHUCKING ARM SUPPLIED When replacing chucking arm on CDP-255, the part listed in theS/M is different than original part. Specifically the magnet assy wasnot matched to the spindle so the chucking arm would not properly clampthe disc.
SonyITA650
SPEAKERPHONE PROBLEM Outgoing audio loud and quiet, only when speakerphone is used.
SonyCDP707ESD
NO PLAY (KEEP TURNING THE DISC) 1) FOP sled lock lever was out of position and prevented FOPfrom getting into inner position. 2) No part number for this lock lever.
SonyWMF46
MOTOR HUM (ELECTRICAL) Above replacement motor produces a low level (Hum) audiblein headphones. Used all parts that came with motor - screws, cushions,etc. Large amplitude pulse can be seen on scope on black lead wire ofmotor. Hum goes away when (Pause) is activated. -HQ C
SonyVTX1100R
DISPLAY ON MONITOR (KX) HAS A RIPPLING EFFECT The VTX1100R tuner came in dead. The line fuse F201 (1.6A)was blown. The fuse was replaced and the unit worked. The picture on theKX-1901A monitor was good however, the display had a rippling effect.
SonyKV4000
INTERMITTENT VHF TUNING The VHF high channels could not be selected intermittently.We found switch, S-901, to have developed a resistance of about 400 OHMS.This condition did not allow a complete (Low) state in the band-selectflip-flop, causing set to skip to UHF from VHF low.
SonyD7
PART NUMBER MISSING A part number is needed for the cloth tape used in portable CDplayers to hold down wires in place. -HQ COMMENTS: The part number is 3-831-441-XX.
SonyD10
PART NUMBER MISSING A part number is needed for the cloth tape used in portable CDplayers to hold down wires in place. -HQ COMMENTS: The part number is 3-831-441-XX.
SonyKV2780R
INTERFERENCE PATTERN, REPLACE IC-651 REGULATOR During first 15 minutes of operation, set displayed an inter-ference pattern on the screen resembling thin horizontal lines about 1/4to 1/2 inch apart, accompanied by a high-pitched squeal. This patternwas more noticeable on a bright scene. By bringing
SonyXR66
SPURIOUS AUTO-REVERSE WITH NEW SYSCON IC (IC801) Unit would falsely auto-reverse toward the end of a tape. Noproblem noted with rotation sensor outputs. Original IC801 wasTC9310N-050. New sub is TC9312N-040.
SonyEVS700U
SHUT DOWN AT END OF TAPE Unit would shut down at end of tape. Would not rewind. Nofunctions except eject. Acted as if end sensor was bad. Replaced, butsame problem. DC voltages were correct at sensors and Q104 and Q103 on(MD-8) board.
SonyCCDV5
PART NUMBER FOR .25A FUSE TYPE SSFR (DEAD SET) Fuse not listed - need part number. -HQ COMMENTS: The correct part number is 1-532-770-21.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads